Cargando…

Development of a power meter equipped target for ISOLDE RILIS

The resonance ionization laser ion source (RILIS) at the ISOLDE on-line isotope separator is based on the selective excitation of atomic transitions by tuneable laser radiation. RILIS has become more and more important and is today requested by the ISOLDE users for more than 50% of the time. Up to t...

Descripción completa

Detalles Bibliográficos
Autor principal: Zadvornaya, Alexandra
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1618369
_version_ 1780932916704968704
author Zadvornaya, Alexandra
author_facet Zadvornaya, Alexandra
author_sort Zadvornaya, Alexandra
collection CERN
description The resonance ionization laser ion source (RILIS) at the ISOLDE on-line isotope separator is based on the selective excitation of atomic transitions by tuneable laser radiation. RILIS has become more and more important and is today requested by the ISOLDE users for more than 50% of the time. Up to three independent laser beams are sent from the laser installation to the ISOLDE frontend where the target and ion source is mounted [1]. To monitor the beam position, a virtual reference point is generated inside the laser room by means of a quarts plate, mounted half way between laser table and ion source. A reflection from this surface allows monitoring the laser beam positions in the reference point.
id cern-1618369
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2013
record_format invenio
spelling cern-16183692019-09-30T06:29:59Zhttp://cds.cern.ch/record/1618369engZadvornaya, AlexandraDevelopment of a power meter equipped target for ISOLDE RILISOther SubjectsThe resonance ionization laser ion source (RILIS) at the ISOLDE on-line isotope separator is based on the selective excitation of atomic transitions by tuneable laser radiation. RILIS has become more and more important and is today requested by the ISOLDE users for more than 50% of the time. Up to three independent laser beams are sent from the laser installation to the ISOLDE frontend where the target and ion source is mounted [1]. To monitor the beam position, a virtual reference point is generated inside the laser room by means of a quarts plate, mounted half way between laser table and ion source. A reflection from this surface allows monitoring the laser beam positions in the reference point.CERN-STUDENTS-Note-2013-247oai:cds.cern.ch:16183692013-10-25
spellingShingle Other Subjects
Zadvornaya, Alexandra
Development of a power meter equipped target for ISOLDE RILIS
title Development of a power meter equipped target for ISOLDE RILIS
title_full Development of a power meter equipped target for ISOLDE RILIS
title_fullStr Development of a power meter equipped target for ISOLDE RILIS
title_full_unstemmed Development of a power meter equipped target for ISOLDE RILIS
title_short Development of a power meter equipped target for ISOLDE RILIS
title_sort development of a power meter equipped target for isolde rilis
topic Other Subjects
url http://cds.cern.ch/record/1618369
work_keys_str_mv AT zadvornayaalexandra developmentofapowermeterequippedtargetforisolderilis