Cargando…

Quantitative Outgassing studies in DC Electrical breakdown

Breakdown in the accelerating structures sets an important limit to the performance of the CLIC linear collider. Vacuum degradation and subsequent beam instability are possible outcomes of a breakdown if too much gas is released from the cavity surface. Quantitative data of gas released by breakdown...

Descripción completa

Detalles Bibliográficos
Autores principales: Levinsen, Yngve Inntjore, Descoeudres, A, Calatroni, Sergio, Taborelli, Mauro, Wünsch, Walter
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1621649
_version_ 1780933202974605312
author Levinsen, Yngve Inntjore
Descoeudres, A
Calatroni, Sergio
Taborelli, Mauro
Wünsch, Walter
author_facet Levinsen, Yngve Inntjore
Descoeudres, A
Calatroni, Sergio
Taborelli, Mauro
Wünsch, Walter
author_sort Levinsen, Yngve Inntjore
collection CERN
description Breakdown in the accelerating structures sets an important limit to the performance of the CLIC linear collider. Vacuum degradation and subsequent beam instability are possible outcomes of a breakdown if too much gas is released from the cavity surface. Quantitative data of gas released by breakdowns are provided for copper (milled Cu-OFE, as-received and heat-treated), and molybdenum. These data are produced in a DC spark system based on a capacitance charged at fixed energy, and will serve as a reference for the vacuum design of the CLIC accelerating structures.
id cern-1621649
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2013
record_format invenio
spelling cern-16216492023-07-20T15:07:11Zhttp://cds.cern.ch/record/1621649engLevinsen, Yngve InntjoreDescoeudres, ACalatroni, SergioTaborelli, MauroWünsch, WalterQuantitative Outgassing studies in DC Electrical breakdownAccelerators and Storage RingsBreakdown in the accelerating structures sets an important limit to the performance of the CLIC linear collider. Vacuum degradation and subsequent beam instability are possible outcomes of a breakdown if too much gas is released from the cavity surface. Quantitative data of gas released by breakdowns are provided for copper (milled Cu-OFE, as-received and heat-treated), and molybdenum. These data are produced in a DC spark system based on a capacitance charged at fixed energy, and will serve as a reference for the vacuum design of the CLIC accelerating structures.CERN-OPEN-2013-035CLIC-Note-797oai:cds.cern.ch:16216492013-10-28
spellingShingle Accelerators and Storage Rings
Levinsen, Yngve Inntjore
Descoeudres, A
Calatroni, Sergio
Taborelli, Mauro
Wünsch, Walter
Quantitative Outgassing studies in DC Electrical breakdown
title Quantitative Outgassing studies in DC Electrical breakdown
title_full Quantitative Outgassing studies in DC Electrical breakdown
title_fullStr Quantitative Outgassing studies in DC Electrical breakdown
title_full_unstemmed Quantitative Outgassing studies in DC Electrical breakdown
title_short Quantitative Outgassing studies in DC Electrical breakdown
title_sort quantitative outgassing studies in dc electrical breakdown
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1621649
work_keys_str_mv AT levinsenyngveinntjore quantitativeoutgassingstudiesindcelectricalbreakdown
AT descoeudresa quantitativeoutgassingstudiesindcelectricalbreakdown
AT calatronisergio quantitativeoutgassingstudiesindcelectricalbreakdown
AT taborellimauro quantitativeoutgassingstudiesindcelectricalbreakdown
AT wunschwalter quantitativeoutgassingstudiesindcelectricalbreakdown