Cargando…

Simultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede II

The CMS silicon tracker consists of 25 684 sensors that provide measurements of trajectories of charged particles that are used by almost every physics analysis at CMS. In order to achieve high measurement precision, the positions and orientations of all sensors have to be determined very accurately...

Descripción completa

Detalles Bibliográficos
Autor principal: Bartosik, Nazar
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1629513
_version_ 1780934139172618240
author Bartosik, Nazar
author_facet Bartosik, Nazar
author_sort Bartosik, Nazar
collection CERN
description The CMS silicon tracker consists of 25 684 sensors that provide measurements of trajectories of charged particles that are used by almost every physics analysis at CMS. In order to achieve high measurement precision, the positions and orientations of all sensors have to be determined very accurately. This is achieved by track-based alignment using the global fit approach of the Millepede II program. This approach is capable of determining about 200 000 parameters simultaneously.The alignment precision reached such a high level that even small calibration inaccuracies are noticeable. Therefore the alignment framework has been extended to treat position sensitive calibration parameters. Of special interest is the Lorentz angle which affects the hit positions due to the drift of the signal electrons in the magnetic field. We present the results from measurements of the Lorentz angle and its time dependence during full 2012 data taking period as well as general description of the alignment and calibration procedure.
id cern-1629513
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2013
record_format invenio
spelling cern-16295132019-09-30T06:29:59Zhttp://cds.cern.ch/record/1629513engBartosik, NazarSimultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede IIDetectors and Experimental TechniquesThe CMS silicon tracker consists of 25 684 sensors that provide measurements of trajectories of charged particles that are used by almost every physics analysis at CMS. In order to achieve high measurement precision, the positions and orientations of all sensors have to be determined very accurately. This is achieved by track-based alignment using the global fit approach of the Millepede II program. This approach is capable of determining about 200 000 parameters simultaneously.The alignment precision reached such a high level that even small calibration inaccuracies are noticeable. Therefore the alignment framework has been extended to treat position sensitive calibration parameters. Of special interest is the Lorentz angle which affects the hit positions due to the drift of the signal electrons in the magnetic field. We present the results from measurements of the Lorentz angle and its time dependence during full 2012 data taking period as well as general description of the alignment and calibration procedure.CMS-CR-2013-343oai:cds.cern.ch:16295132013-10-19
spellingShingle Detectors and Experimental Techniques
Bartosik, Nazar
Simultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede II
title Simultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede II
title_full Simultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede II
title_fullStr Simultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede II
title_full_unstemmed Simultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede II
title_short Simultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede II
title_sort simultaneous alignment and lorentz angle calibration in the cms silicon tracker using millepede ii
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1629513