Cargando…

Energy measurement and longitudinal beam emittance reconstruction in L4T line

LINAC4 is a new linear accelerator for H- ion which will replace proton Linac2 as injector for the CERN proton accelerator complex. LINAC4 accelerates H− ions from 45 keV to 160 MeV in a sequence of normal conducting structures. Then, H- ions with a kinetic energy of 160 MeV will be sent to the PS B...

Descripción completa

Detalles Bibliográficos
Autores principales: Meng, C, Dimov, V A, Garoby, R, Lallement, JB, Lombardi, A, Tang, J Y, Yarmohammadi Satri, M
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1635713
_version_ 1780934536361672704
author Meng, C
Dimov, V A
Garoby, R
Lallement, JB
Lombardi, A
Tang, J Y
Yarmohammadi Satri, M
author_facet Meng, C
Dimov, V A
Garoby, R
Lallement, JB
Lombardi, A
Tang, J Y
Yarmohammadi Satri, M
author_sort Meng, C
collection CERN
description LINAC4 is a new linear accelerator for H- ion which will replace proton Linac2 as injector for the CERN proton accelerator complex. LINAC4 accelerates H− ions from 45 keV to 160 MeV in a sequence of normal conducting structures. Then, H- ions with a kinetic energy of 160 MeV will be sent to the PS Booster. This note describes two energy measurement methods and a improved method that will be used for longitudinal emittance reconstruction with space charge by multi-particle tracking code and the expected results.
id cern-1635713
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2013
record_format invenio
spelling cern-16357132023-08-04T20:26:48Zhttp://cds.cern.ch/record/1635713engMeng, CDimov, V AGaroby, RLallement, JBLombardi, ATang, J YYarmohammadi Satri, MEnergy measurement and longitudinal beam emittance reconstruction in L4T lineAccelerators and Storage RingsLINAC4 is a new linear accelerator for H- ion which will replace proton Linac2 as injector for the CERN proton accelerator complex. LINAC4 accelerates H− ions from 45 keV to 160 MeV in a sequence of normal conducting structures. Then, H- ions with a kinetic energy of 160 MeV will be sent to the PS Booster. This note describes two energy measurement methods and a improved method that will be used for longitudinal emittance reconstruction with space charge by multi-particle tracking code and the expected results.CERN-ACC-Note-2013-0045oai:cds.cern.ch:16357132013-12-10
spellingShingle Accelerators and Storage Rings
Meng, C
Dimov, V A
Garoby, R
Lallement, JB
Lombardi, A
Tang, J Y
Yarmohammadi Satri, M
Energy measurement and longitudinal beam emittance reconstruction in L4T line
title Energy measurement and longitudinal beam emittance reconstruction in L4T line
title_full Energy measurement and longitudinal beam emittance reconstruction in L4T line
title_fullStr Energy measurement and longitudinal beam emittance reconstruction in L4T line
title_full_unstemmed Energy measurement and longitudinal beam emittance reconstruction in L4T line
title_short Energy measurement and longitudinal beam emittance reconstruction in L4T line
title_sort energy measurement and longitudinal beam emittance reconstruction in l4t line
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1635713
work_keys_str_mv AT mengc energymeasurementandlongitudinalbeamemittancereconstructioninl4tline
AT dimovva energymeasurementandlongitudinalbeamemittancereconstructioninl4tline
AT garobyr energymeasurementandlongitudinalbeamemittancereconstructioninl4tline
AT lallementjb energymeasurementandlongitudinalbeamemittancereconstructioninl4tline
AT lombardia energymeasurementandlongitudinalbeamemittancereconstructioninl4tline
AT tangjy energymeasurementandlongitudinalbeamemittancereconstructioninl4tline
AT yarmohammadisatrim energymeasurementandlongitudinalbeamemittancereconstructioninl4tline