Cargando…

Actions to Mitigate the Radiation Damage to Electronics at the LHC

The level of flux of hadrons with energy in the multi MeV range expected from the collisions at the Large Hadron Collider (LHC) interaction Points 1, 5 and 8 and from the collimation system at Point 7 will induce Single Event Errors (SEEs) in the standard electronics present in many of the control e...

Descripción completa

Detalles Bibliográficos
Autores principales: Perrot, A L, Barberan Marin, M, Corso, J P, Foraz, K, Lazzaroni, M, Muttoni, Y
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1636182
_version_ 1780934553023545344
author Perrot, A L
Barberan Marin, M
Corso, J P
Foraz, K
Lazzaroni, M
Muttoni, Y
author_facet Perrot, A L
Barberan Marin, M
Corso, J P
Foraz, K
Lazzaroni, M
Muttoni, Y
author_sort Perrot, A L
collection CERN
description The level of flux of hadrons with energy in the multi MeV range expected from the collisions at the Large Hadron Collider (LHC) interaction Points 1, 5 and 8 and from the collimation system at Point 7 will induce Single Event Errors (SEEs) in the standard electronics present in many of the control equipment installed in LHC underground. Furthermore, a risk of SEEs induced by thermal neutrons cannot be excluded. Such events would perturb the LHC operation, possibly leading to a stop of the machine. Main mitigation actions will be implemented during the first LHC Long Shutdown of 2013/2014 (LS1) to reduce the SEE occurrence. This paper summarizes the mitigation measures and their associated foreseen improvements in terms of SEE. It presents the organization process and associated planning, highlighting the impacts on the overall LHC LS1 planning and the main concerns during implementation.
id cern-1636182
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2013
record_format invenio
spelling cern-16361822022-08-10T21:06:51Zhttp://cds.cern.ch/record/1636182engPerrot, A LBarberan Marin, MCorso, J PForaz, KLazzaroni, MMuttoni, YActions to Mitigate the Radiation Damage to Electronics at the LHCAccelerators and Storage RingsThe level of flux of hadrons with energy in the multi MeV range expected from the collisions at the Large Hadron Collider (LHC) interaction Points 1, 5 and 8 and from the collimation system at Point 7 will induce Single Event Errors (SEEs) in the standard electronics present in many of the control equipment installed in LHC underground. Furthermore, a risk of SEEs induced by thermal neutrons cannot be excluded. Such events would perturb the LHC operation, possibly leading to a stop of the machine. Main mitigation actions will be implemented during the first LHC Long Shutdown of 2013/2014 (LS1) to reduce the SEE occurrence. This paper summarizes the mitigation measures and their associated foreseen improvements in terms of SEE. It presents the organization process and associated planning, highlighting the impacts on the overall LHC LS1 planning and the main concerns during implementation.CERN-ACC-2013-0290oai:cds.cern.ch:16361822013-05-08
spellingShingle Accelerators and Storage Rings
Perrot, A L
Barberan Marin, M
Corso, J P
Foraz, K
Lazzaroni, M
Muttoni, Y
Actions to Mitigate the Radiation Damage to Electronics at the LHC
title Actions to Mitigate the Radiation Damage to Electronics at the LHC
title_full Actions to Mitigate the Radiation Damage to Electronics at the LHC
title_fullStr Actions to Mitigate the Radiation Damage to Electronics at the LHC
title_full_unstemmed Actions to Mitigate the Radiation Damage to Electronics at the LHC
title_short Actions to Mitigate the Radiation Damage to Electronics at the LHC
title_sort actions to mitigate the radiation damage to electronics at the lhc
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1636182
work_keys_str_mv AT perrotal actionstomitigatetheradiationdamagetoelectronicsatthelhc
AT barberanmarinm actionstomitigatetheradiationdamagetoelectronicsatthelhc
AT corsojp actionstomitigatetheradiationdamagetoelectronicsatthelhc
AT forazk actionstomitigatetheradiationdamagetoelectronicsatthelhc
AT lazzaronim actionstomitigatetheradiationdamagetoelectronicsatthelhc
AT muttoniy actionstomitigatetheradiationdamagetoelectronicsatthelhc