Cargando…

10 Orders of Magnitude Current Measurement Digitisers for the CERN Beam Loss Systems

A wide range current digitizer card is needed for the acquisition module of the beam loss monitoring systems in the CERN Injector Complex. The fully differential frequency converter allows measuring positive and negative input currents with a resolution of 31nA in an integration window of 2μs. Incre...

Descripción completa

Detalles Bibliográficos
Autores principales: Vigano, W, Alsdorf, M, Dehning, B, Kwiatkowski, M, Venturini, G G, Zamantzas, C
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/9/02/C02011
http://cds.cern.ch/record/1642136
Descripción
Sumario:A wide range current digitizer card is needed for the acquisition module of the beam loss monitoring systems in the CERN Injector Complex. The fully differential frequency converter allows measuring positive and negative input currents with a resolution of 31nA in an integration window of 2μs. Increasing the integration window, the dynamic range covers 2•1010 were the upper part of the range is converted by measuring directly the voltage drop on a resistor. The key elements of this design are the fully differential integrator and the switches operated by an FPGA. The circuit is designed to avoid any dead time in the acquisition and reliability and failsafe operational considerations are main design goals. The circuit will be discussed in detail and lab and field measurements will be shown.