Cargando…
The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System
The Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN. The Detector Control System (DCS) that had been developed and implemented for the CMS ECAL was deployed in accordance with the LHC schedule and...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1670277 |
_version_ | 1780935564036407296 |
---|---|
author | Holme, Oliver Adzic, P Calafiori, D Di Dissertori, G Djambazov, L Jovanovic, D Lustermann, W Zelepoukine, S |
author_facet | Holme, Oliver Adzic, P Calafiori, D Di Dissertori, G Djambazov, L Jovanovic, D Lustermann, W Zelepoukine, S |
author_sort | Holme, Oliver |
collection | CERN |
description | The Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN. The Detector Control System (DCS) that had been developed and implemented for the CMS ECAL was deployed in accordance with the LHC schedule and has been supporting the CMS data-taking since LHC physics runs started in 2009. During these years, the control system has been regularly adapted according to operational experience and new requirements, always respecting the constraints imposed on significant changes to a running system. Several hardware and software upgrades and system extensions were therefore deferred to the first LHC Long Shutdown (LS1). This paper presents the main architectural differences between the system that supported the CMS ECAL during its first years and the new design for the coming physics runs after LS1. Details on the upgrade planning, including the certification methods performed in the CMS ECAL DCS laboratory facilities, reports on the implementation progress and the expectations for the post-LS1 system are highlighted. |
id | cern-1670277 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2013 |
record_format | invenio |
spelling | cern-16702772019-09-30T06:29:59Zhttp://cds.cern.ch/record/1670277engHolme, OliverAdzic, PCalafiori, D DiDissertori, GDjambazov, LJovanovic, DLustermann, WZelepoukine, SThe upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control SystemDetectors and Experimental TechniquesThe Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN. The Detector Control System (DCS) that had been developed and implemented for the CMS ECAL was deployed in accordance with the LHC schedule and has been supporting the CMS data-taking since LHC physics runs started in 2009. During these years, the control system has been regularly adapted according to operational experience and new requirements, always respecting the constraints imposed on significant changes to a running system. Several hardware and software upgrades and system extensions were therefore deferred to the first LHC Long Shutdown (LS1). This paper presents the main architectural differences between the system that supported the CMS ECAL during its first years and the new design for the coming physics runs after LS1. Details on the upgrade planning, including the certification methods performed in the CMS ECAL DCS laboratory facilities, reports on the implementation progress and the expectations for the post-LS1 system are highlighted.CMS-CR-2013-323oai:cds.cern.ch:16702772013 |
spellingShingle | Detectors and Experimental Techniques Holme, Oliver Adzic, P Calafiori, D Di Dissertori, G Djambazov, L Jovanovic, D Lustermann, W Zelepoukine, S The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System |
title | The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System |
title_full | The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System |
title_fullStr | The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System |
title_full_unstemmed | The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System |
title_short | The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System |
title_sort | upgrade and re-validation of the compact muon solenoid electromagnetic calorimeter control system |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1670277 |
work_keys_str_mv | AT holmeoliver theupgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT adzicp theupgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT calafioriddi theupgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT dissertorig theupgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT djambazovl theupgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT jovanovicd theupgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT lustermannw theupgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT zelepoukines theupgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT holmeoliver upgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT adzicp upgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT calafioriddi upgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT dissertorig upgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT djambazovl upgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT jovanovicd upgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT lustermannw upgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem AT zelepoukines upgradeandrevalidationofthecompactmuonsolenoidelectromagneticcalorimetercontrolsystem |