Cargando…
The CALICE digital hadron calorimeter: calibration and response to pions and positrons
The large CALICE Digital Hadron Calorimeter prototype (DHCAL) was built in 2009 - 2010. The DHCAL uses Resistive Plate Chambers (RPCs) as active media and is read out with 1 x 1 cm2 pads and digital (1 - bit) resolution. With a world record of about 0.5M readout channels, the DHCAL offers the possib...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1692761 |
_version_ | 1780935889794367488 |
---|---|
author | Bilki, Burak |
author_facet | Bilki, Burak |
author_sort | Bilki, Burak |
collection | CERN |
description | The large CALICE Digital Hadron Calorimeter prototype (DHCAL) was built in 2009 - 2010. The DHCAL uses Resistive Plate Chambers (RPCs) as active media and is read out with 1 x 1 cm2 pads and digital (1 - bit) resolution. With a world record of about 0.5M readout channels, the DHCAL offers the possibility to study hadronic interactions with unprecedented spatial resolution. This talk reports on the results from the analysis of pion events of momenta between 2 to 60 GeV/c collected in the Fermilab test beam with an emphasis on the intricate calibration procedures. |
id | cern-1692761 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-16927612023-03-14T18:25:00Zhttp://cds.cern.ch/record/1692761engBilki, BurakThe CALICE digital hadron calorimeter: calibration and response to pions and positronshep-exParticle Physics - Experimentphysics.ins-detDetectors and Experimental TechniquesThe large CALICE Digital Hadron Calorimeter prototype (DHCAL) was built in 2009 - 2010. The DHCAL uses Resistive Plate Chambers (RPCs) as active media and is read out with 1 x 1 cm2 pads and digital (1 - bit) resolution. With a world record of about 0.5M readout channels, the DHCAL offers the possibility to study hadronic interactions with unprecedented spatial resolution. This talk reports on the results from the analysis of pion events of momenta between 2 to 60 GeV/c collected in the Fermilab test beam with an emphasis on the intricate calibration procedures.arXiv:1404.0041oai:cds.cern.ch:16927612014-03-31 |
spellingShingle | hep-ex Particle Physics - Experiment physics.ins-det Detectors and Experimental Techniques Bilki, Burak The CALICE digital hadron calorimeter: calibration and response to pions and positrons |
title | The CALICE digital hadron calorimeter: calibration and response to pions and positrons |
title_full | The CALICE digital hadron calorimeter: calibration and response to pions and positrons |
title_fullStr | The CALICE digital hadron calorimeter: calibration and response to pions and positrons |
title_full_unstemmed | The CALICE digital hadron calorimeter: calibration and response to pions and positrons |
title_short | The CALICE digital hadron calorimeter: calibration and response to pions and positrons |
title_sort | calice digital hadron calorimeter: calibration and response to pions and positrons |
topic | hep-ex Particle Physics - Experiment physics.ins-det Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1692761 |
work_keys_str_mv | AT bilkiburak thecalicedigitalhadroncalorimetercalibrationandresponsetopionsandpositrons AT bilkiburak calicedigitalhadroncalorimetercalibrationandresponsetopionsandpositrons |