AC dipole based optics measurement and correction at RHIC
Independent component analysis (ICA) was applied to the AC dipole based optics measurement at RHIC to extract beta functions as well as phase advances at each BPM. Existence of excessive beta-beat was observed in both rings of RHIC at polarized proton store energy. A unique global optics correction...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1701088 |
_version_ | 1780936255538724864 |
---|---|
author | Shen, X Lee, S Y Bai, M White, S Robert-Domolaize, G Luo, Y Marusic, A Tomas, R |
author_facet | Shen, X Lee, S Y Bai, M White, S Robert-Domolaize, G Luo, Y Marusic, A Tomas, R |
author_sort | Shen, X |
collection | CERN |
description | Independent component analysis (ICA) was applied to the AC dipole based optics measurement at RHIC to extract beta functions as well as phase advances at each BPM. Existence of excessive beta-beat was observed in both rings of RHIC at polarized proton store energy. A unique global optics correction scheme was then developed and tested successfully during the RHIC polarized proton run in 2013. The feasibility of using horizontal closed orbit bump at sextupole for arc beta-beat correction was also demonstrated. |
id | cern-1701088 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2013 |
record_format | invenio |
spelling | cern-17010882022-08-17T13:31:15Zhttp://cds.cern.ch/record/1701088engShen, XLee, S YBai, MWhite, SRobert-Domolaize, GLuo, YMarusic, ATomas, RAC dipole based optics measurement and correction at RHICAccelerators and Storage RingsIndependent component analysis (ICA) was applied to the AC dipole based optics measurement at RHIC to extract beta functions as well as phase advances at each BPM. Existence of excessive beta-beat was observed in both rings of RHIC at polarized proton store energy. A unique global optics correction scheme was then developed and tested successfully during the RHIC polarized proton run in 2013. The feasibility of using horizontal closed orbit bump at sextupole for arc beta-beat correction was also demonstrated.oai:cds.cern.ch:17010882013 |
spellingShingle | Accelerators and Storage Rings Shen, X Lee, S Y Bai, M White, S Robert-Domolaize, G Luo, Y Marusic, A Tomas, R AC dipole based optics measurement and correction at RHIC |
title | AC dipole based optics measurement and correction at RHIC |
title_full | AC dipole based optics measurement and correction at RHIC |
title_fullStr | AC dipole based optics measurement and correction at RHIC |
title_full_unstemmed | AC dipole based optics measurement and correction at RHIC |
title_short | AC dipole based optics measurement and correction at RHIC |
title_sort | ac dipole based optics measurement and correction at rhic |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1701088 |
work_keys_str_mv | AT shenx acdipolebasedopticsmeasurementandcorrectionatrhic AT leesy acdipolebasedopticsmeasurementandcorrectionatrhic AT baim acdipolebasedopticsmeasurementandcorrectionatrhic AT whites acdipolebasedopticsmeasurementandcorrectionatrhic AT robertdomolaizeg acdipolebasedopticsmeasurementandcorrectionatrhic AT luoy acdipolebasedopticsmeasurementandcorrectionatrhic AT marusica acdipolebasedopticsmeasurementandcorrectionatrhic AT tomasr acdipolebasedopticsmeasurementandcorrectionatrhic |