Cargando…

CMS Forward Calorimeters Phase II Upgrade

The Phase II Upgrade of the CMS forward calorimeters (electromagnetic and hadronic) originates from the fact that these calorimeters will not be sufficiently performant with the expected HL-LHC (High Luminosity LHC) conditions. The major challenge is to preserve/improve the high performance of the c...

Descripción completa

Detalles Bibliográficos
Autor principal: Bilki, Burak
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1742-6596/587/1/012014
http://cds.cern.ch/record/1702271
_version_ 1780936297809969152
author Bilki, Burak
author_facet Bilki, Burak
author_sort Bilki, Burak
collection CERN
description The Phase II Upgrade of the CMS forward calorimeters (electromagnetic and hadronic) originates from the fact that these calorimeters will not be sufficiently performant with the expected HL-LHC (High Luminosity LHC) conditions. The major challenge is to preserve/improve the high performance of the current forward detectors with new devices that can withstand the unprecedented radiation levels and disentangle the very large event pileup. Here, we present an overview of the various upgrade options being considered by CMS, explaining the detector concepts and current/future beam test activities.
id cern-1702271
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-17022712022-08-10T13:05:27Zdoi:10.1088/1742-6596/587/1/012014http://cds.cern.ch/record/1702271engBilki, BurakCMS Forward Calorimeters Phase II UpgradeDetectors and Experimental TechniquesThe Phase II Upgrade of the CMS forward calorimeters (electromagnetic and hadronic) originates from the fact that these calorimeters will not be sufficiently performant with the expected HL-LHC (High Luminosity LHC) conditions. The major challenge is to preserve/improve the high performance of the current forward detectors with new devices that can withstand the unprecedented radiation levels and disentangle the very large event pileup. Here, we present an overview of the various upgrade options being considered by CMS, explaining the detector concepts and current/future beam test activities.CMS-CR-2014-069oai:cds.cern.ch:17022712014-05-13
spellingShingle Detectors and Experimental Techniques
Bilki, Burak
CMS Forward Calorimeters Phase II Upgrade
title CMS Forward Calorimeters Phase II Upgrade
title_full CMS Forward Calorimeters Phase II Upgrade
title_fullStr CMS Forward Calorimeters Phase II Upgrade
title_full_unstemmed CMS Forward Calorimeters Phase II Upgrade
title_short CMS Forward Calorimeters Phase II Upgrade
title_sort cms forward calorimeters phase ii upgrade
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1742-6596/587/1/012014
http://cds.cern.ch/record/1702271
work_keys_str_mv AT bilkiburak cmsforwardcalorimetersphaseiiupgrade