Magnetic Interference Estimation on HIE-ISOLDE’s Beam Transfer Lines Diagnostic Box Stepper Motors’ Operation

The aim of the HIE-ISOLDE project is to expand the physics programme compared to that of REX-ISOLDE. In total, 13 Diagnostic Boxes shall be installed in close proximity to the horizontal/vertical corrector magnets (steerers).The steerers’ shall have a maximum integrated magnetic field of 9.1 Tmm and...

Descripción completa

Detalles Bibliográficos
Autor principal: Farantatos, P
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1706162
_version_ 1780936479321620480
author Farantatos, P
author_facet Farantatos, P
author_sort Farantatos, P
collection CERN
description The aim of the HIE-ISOLDE project is to expand the physics programme compared to that of REX-ISOLDE. In total, 13 Diagnostic Boxes shall be installed in close proximity to the horizontal/vertical corrector magnets (steerers).The steerers’ shall have a maximum integrated magnetic field of 9.1 Tmm and their stray magnetic field could potentially cause perturbations to the nominal operation of the Diagnostic Boxes’ Stepper Motors due to magnetic interference. In the present report, the maximum stray magnetic field interference numerical calculation method in the volume occupied by the stepper motors is presented, followed by estimation results.
id cern-1706162
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-17061622023-08-04T20:26:13Zhttp://cds.cern.ch/record/1706162engFarantatos, PMagnetic Interference Estimation on HIE-ISOLDE’s Beam Transfer Lines Diagnostic Box Stepper Motors’ OperationAccelerators and Storage RingsThe aim of the HIE-ISOLDE project is to expand the physics programme compared to that of REX-ISOLDE. In total, 13 Diagnostic Boxes shall be installed in close proximity to the horizontal/vertical corrector magnets (steerers).The steerers’ shall have a maximum integrated magnetic field of 9.1 Tmm and their stray magnetic field could potentially cause perturbations to the nominal operation of the Diagnostic Boxes’ Stepper Motors due to magnetic interference. In the present report, the maximum stray magnetic field interference numerical calculation method in the volume occupied by the stepper motors is presented, followed by estimation results.CERN-ACC-Note-2014-0035oai:cds.cern.ch:17061622014
spellingShingle Accelerators and Storage Rings
Farantatos, P
Magnetic Interference Estimation on HIE-ISOLDE’s Beam Transfer Lines Diagnostic Box Stepper Motors’ Operation
title Magnetic Interference Estimation on HIE-ISOLDE’s Beam Transfer Lines Diagnostic Box Stepper Motors’ Operation
title_full Magnetic Interference Estimation on HIE-ISOLDE’s Beam Transfer Lines Diagnostic Box Stepper Motors’ Operation
title_fullStr Magnetic Interference Estimation on HIE-ISOLDE’s Beam Transfer Lines Diagnostic Box Stepper Motors’ Operation
title_full_unstemmed Magnetic Interference Estimation on HIE-ISOLDE’s Beam Transfer Lines Diagnostic Box Stepper Motors’ Operation
title_short Magnetic Interference Estimation on HIE-ISOLDE’s Beam Transfer Lines Diagnostic Box Stepper Motors’ Operation
title_sort magnetic interference estimation on hie-isolde’s beam transfer lines diagnostic box stepper motors’ operation
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1706162
work_keys_str_mv AT farantatosp magneticinterferenceestimationonhieisoldesbeamtransferlinesdiagnosticboxsteppermotorsoperation