Cargando…
Multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets
A correction of field gradients in quadrupole accelerator magnets measured by stretched-wire methods is described. The gradient is first measured by means of the single-stretched-wire method. By using the same experimental setup, the relative multipole-field errors of the quadrupole are then measure...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/8/08/P08010 http://cds.cern.ch/record/1709405 |
_version_ | 1780936641202880512 |
---|---|
author | Arpaia, P Buzio, M Petrone, C Russenschuck, S Walckiers, L |
author_facet | Arpaia, P Buzio, M Petrone, C Russenschuck, S Walckiers, L |
author_sort | Arpaia, P |
collection | CERN |
description | A correction of field gradients in quadrupole accelerator magnets measured by stretched-wire methods is described. The gradient is first measured by means of the single-stretched-wire method. By using the same experimental setup, the relative multipole-field errors of the quadrupole are then measured by means of the oscillating-wire technique and used for the correction scheme. Results of the experimental validation are presented for a prototype quadrupole for the CLIC accelerator study at CERN. |
id | cern-1709405 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2013 |
record_format | invenio |
spelling | cern-17094052022-08-10T20:14:05Zdoi:10.1088/1748-0221/8/08/P08010http://cds.cern.ch/record/1709405engArpaia, PBuzio, MPetrone, CRussenschuck, SWalckiers, LMultipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnetsAccelerators and Storage RingsA correction of field gradients in quadrupole accelerator magnets measured by stretched-wire methods is described. The gradient is first measured by means of the single-stretched-wire method. By using the same experimental setup, the relative multipole-field errors of the quadrupole are then measured by means of the oscillating-wire technique and used for the correction scheme. Results of the experimental validation are presented for a prototype quadrupole for the CLIC accelerator study at CERN.oai:cds.cern.ch:17094052013 |
spellingShingle | Accelerators and Storage Rings Arpaia, P Buzio, M Petrone, C Russenschuck, S Walckiers, L Multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets |
title | Multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets |
title_full | Multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets |
title_fullStr | Multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets |
title_full_unstemmed | Multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets |
title_short | Multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets |
title_sort | multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1088/1748-0221/8/08/P08010 http://cds.cern.ch/record/1709405 |
work_keys_str_mv | AT arpaiap multipolecorrectionofstretchedwiremeasurementsoffieldgradientsinquadrupoleacceleratormagnets AT buziom multipolecorrectionofstretchedwiremeasurementsoffieldgradientsinquadrupoleacceleratormagnets AT petronec multipolecorrectionofstretchedwiremeasurementsoffieldgradientsinquadrupoleacceleratormagnets AT russenschucks multipolecorrectionofstretchedwiremeasurementsoffieldgradientsinquadrupoleacceleratormagnets AT walckiersl multipolecorrectionofstretchedwiremeasurementsoffieldgradientsinquadrupoleacceleratormagnets |