Cargando…

One cryogenic collimator, tested with beam

The main accelerator SIS100 of the FAIR-complex will provide heavy ion beams of highest intensities. Beam loss due to ionization is the most demanding loss mechanism at operation with high intensity, intermediate charge state heavy ions. A special synchrotron design has been developed for SIS100, ai...

Descripción completa

Detalles Bibliográficos
Autor principal: EuCARD, Collaboration
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1709824
_version_ 1780936664271552512
author EuCARD, Collaboration
author_facet EuCARD, Collaboration
author_sort EuCARD, Collaboration
collection CERN
description The main accelerator SIS100 of the FAIR-complex will provide heavy ion beams of highest intensities. Beam loss due to ionization is the most demanding loss mechanism at operation with high intensity, intermediate charge state heavy ions. A special synchrotron design has been developed for SIS100, aiming for hundred percent control of ionization beam loss by means of a dedicated cryogenic ion catcher system. To suppress dynamic vacuum effects, the cryocatcher system shall provide a significantly reduced effective desorption yield. The construction and test of a prototype cryocatcher is a task of the EuCARD WP8 ColMat. A prototype test setup, including cryostat has been constructed, manufactured and tested under realistic conditions with beams from the heavy ion synchrotron SIS18. The design and results are presented.
format info:eu-repo/semantics/article
id cern-1709824
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-17098242019-09-30T06:29:59Z http://cds.cern.ch/record/1709824 eng EuCARD, Collaboration One cryogenic collimator, tested with beam Accelerators and Storage Rings 8: Collimators & materials for higher beam power beam The main accelerator SIS100 of the FAIR-complex will provide heavy ion beams of highest intensities. Beam loss due to ionization is the most demanding loss mechanism at operation with high intensity, intermediate charge state heavy ions. A special synchrotron design has been developed for SIS100, aiming for hundred percent control of ionization beam loss by means of a dedicated cryogenic ion catcher system. To suppress dynamic vacuum effects, the cryocatcher system shall provide a significantly reduced effective desorption yield. The construction and test of a prototype cryocatcher is a task of the EuCARD WP8 ColMat. A prototype test setup, including cryostat has been constructed, manufactured and tested under realistic conditions with beams from the heavy ion synchrotron SIS18. The design and results are presented. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1709824 2014
spellingShingle Accelerators and Storage Rings
8: Collimators & materials for higher beam power beam
EuCARD, Collaboration
One cryogenic collimator, tested with beam
title One cryogenic collimator, tested with beam
title_full One cryogenic collimator, tested with beam
title_fullStr One cryogenic collimator, tested with beam
title_full_unstemmed One cryogenic collimator, tested with beam
title_short One cryogenic collimator, tested with beam
title_sort one cryogenic collimator, tested with beam
topic Accelerators and Storage Rings
8: Collimators & materials for higher beam power beam
url http://cds.cern.ch/record/1709824
http://cds.cern.ch/record/1709824
work_keys_str_mv AT eucardcollaboration onecryogeniccollimatortestedwithbeam