Cargando…

Breakdown Localization Studies on the SwissFEL C-band Test Structures

The SwissFEL main LINAC will consist of 104 Cband structures with a nominal accelerating gradient of 28MV/m. First power tests were performed on short constant impedance test-structures composed of eleven double-rounded cups. In order to localize breakdowns, two or three acoustic emission sensors we...

Descripción completa

Detalles Bibliográficos
Autores principales: Klavins, J, Dementjevs, S, Le Pimpec, F, Locans, U, Shipman, N, Stingelin, L, Wohlmuther, M, Zennaro, R
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1709919
_version_ 1780936680223539200
author Klavins, J
Dementjevs, S
Le Pimpec, F
Locans, U
Shipman, N
Stingelin, L
Wohlmuther, M
Zennaro, R
author_facet Klavins, J
Dementjevs, S
Le Pimpec, F
Locans, U
Shipman, N
Stingelin, L
Wohlmuther, M
Zennaro, R
author_sort Klavins, J
collection CERN
description The SwissFEL main LINAC will consist of 104 Cband structures with a nominal accelerating gradient of 28MV/m. First power tests were performed on short constant impedance test-structures composed of eleven double-rounded cups. In order to localize breakdowns, two or three acoustic emission sensors were installed on the test-structures. In order to localize breakdowns we have analysed, in addition to acoustic measurements, the delay and phase of the RF power signals. Parasitic, acoustic noise emitted from the loads of the structure complicated the data interpretation and necessitated appropriate processing of the acoustic signals. The Goals of the experiments were to identify design and manufacturing errors of the structures. The results indicate that breakdowns occur mostly at the input power coupler, as also confirmed by vacuumevents at the same location. The experiments show that the LINAC test-structures fulfil the requirements in breakdown probability. Moreover developing a detection system based on acoustic emission sensors for breakdown localization for our C-band structure seems reasonable given the results obtained.
id cern-1709919
institution Organización Europea para la Investigación Nuclear
publishDate 2013
record_format invenio
spelling cern-17099192019-09-30T06:29:59Zhttp://cds.cern.ch/record/1709919Klavins, JDementjevs, SLe Pimpec, FLocans, UShipman, NStingelin, LWohlmuther, MZennaro, RBreakdown Localization Studies on the SwissFEL C-band Test StructuresAccelerators and Storage RingsThe SwissFEL main LINAC will consist of 104 Cband structures with a nominal accelerating gradient of 28MV/m. First power tests were performed on short constant impedance test-structures composed of eleven double-rounded cups. In order to localize breakdowns, two or three acoustic emission sensors were installed on the test-structures. In order to localize breakdowns we have analysed, in addition to acoustic measurements, the delay and phase of the RF power signals. Parasitic, acoustic noise emitted from the loads of the structure complicated the data interpretation and necessitated appropriate processing of the acoustic signals. The Goals of the experiments were to identify design and manufacturing errors of the structures. The results indicate that breakdowns occur mostly at the input power coupler, as also confirmed by vacuumevents at the same location. The experiments show that the LINAC test-structures fulfil the requirements in breakdown probability. Moreover developing a detection system based on acoustic emission sensors for breakdown localization for our C-band structure seems reasonable given the results obtained.IPAC-2013-WEPFI058oai:cds.cern.ch:17099192013
spellingShingle Accelerators and Storage Rings
Klavins, J
Dementjevs, S
Le Pimpec, F
Locans, U
Shipman, N
Stingelin, L
Wohlmuther, M
Zennaro, R
Breakdown Localization Studies on the SwissFEL C-band Test Structures
title Breakdown Localization Studies on the SwissFEL C-band Test Structures
title_full Breakdown Localization Studies on the SwissFEL C-band Test Structures
title_fullStr Breakdown Localization Studies on the SwissFEL C-band Test Structures
title_full_unstemmed Breakdown Localization Studies on the SwissFEL C-band Test Structures
title_short Breakdown Localization Studies on the SwissFEL C-band Test Structures
title_sort breakdown localization studies on the swissfel c-band test structures
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1709919
work_keys_str_mv AT klavinsj breakdownlocalizationstudiesontheswissfelcbandteststructures
AT dementjevss breakdownlocalizationstudiesontheswissfelcbandteststructures
AT lepimpecf breakdownlocalizationstudiesontheswissfelcbandteststructures
AT locansu breakdownlocalizationstudiesontheswissfelcbandteststructures
AT shipmann breakdownlocalizationstudiesontheswissfelcbandteststructures
AT stingelinl breakdownlocalizationstudiesontheswissfelcbandteststructures
AT wohlmutherm breakdownlocalizationstudiesontheswissfelcbandteststructures
AT zennaror breakdownlocalizationstudiesontheswissfelcbandteststructures