Cargando…
Evaluation results of xTCA equipment for HEP experiments at CERN
The MicroTCA and AdvancedTCA industry standards are candidate modular electronic platforms for the upgrade of the current generation of high energy physics experiments. The PH-ESE group at CERN launched in 2011 the xTCA evaluation project with the aim of performing technical evaluations and eventual...
Autores principales: | , , , , , , |
---|---|
Publicado: |
2013
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/8/12/C12015 http://cds.cern.ch/record/1709945 |
_version_ | 1780936685697105920 |
---|---|
author | Di Cosmo, M Bobillier, V Haas, S Joos, M Mico, S Vasey, F Vichoudis, P |
author_facet | Di Cosmo, M Bobillier, V Haas, S Joos, M Mico, S Vasey, F Vichoudis, P |
author_sort | Di Cosmo, M |
collection | CERN |
description | The MicroTCA and AdvancedTCA industry standards are candidate modular electronic platforms for the upgrade of the current generation of high energy physics experiments. The PH-ESE group at CERN launched in 2011 the xTCA evaluation project with the aim of performing technical evaluations and eventually providing support for commercially available components. Different devices from different vendors have been acquired, evaluated and interoperability tests have been performed. This paper presents the test procedures and facilities that have been developed and focuses on the evaluation results including electrical, thermal and interoperability aspects. |
id | cern-1709945 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2013 |
record_format | invenio |
spelling | cern-17099452019-09-30T06:29:59Zdoi:10.1088/1748-0221/8/12/C12015http://cds.cern.ch/record/1709945Di Cosmo, MBobillier, VHaas, SJoos, MMico, SVasey, FVichoudis, PEvaluation results of xTCA equipment for HEP experiments at CERNDetectors and Experimental TechniquesThe MicroTCA and AdvancedTCA industry standards are candidate modular electronic platforms for the upgrade of the current generation of high energy physics experiments. The PH-ESE group at CERN launched in 2011 the xTCA evaluation project with the aim of performing technical evaluations and eventually providing support for commercially available components. Different devices from different vendors have been acquired, evaluated and interoperability tests have been performed. This paper presents the test procedures and facilities that have been developed and focuses on the evaluation results including electrical, thermal and interoperability aspects.oai:cds.cern.ch:17099452013 |
spellingShingle | Detectors and Experimental Techniques Di Cosmo, M Bobillier, V Haas, S Joos, M Mico, S Vasey, F Vichoudis, P Evaluation results of xTCA equipment for HEP experiments at CERN |
title | Evaluation results of xTCA equipment for HEP experiments at CERN |
title_full | Evaluation results of xTCA equipment for HEP experiments at CERN |
title_fullStr | Evaluation results of xTCA equipment for HEP experiments at CERN |
title_full_unstemmed | Evaluation results of xTCA equipment for HEP experiments at CERN |
title_short | Evaluation results of xTCA equipment for HEP experiments at CERN |
title_sort | evaluation results of xtca equipment for hep experiments at cern |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/8/12/C12015 http://cds.cern.ch/record/1709945 |
work_keys_str_mv | AT dicosmom evaluationresultsofxtcaequipmentforhepexperimentsatcern AT bobillierv evaluationresultsofxtcaequipmentforhepexperimentsatcern AT haass evaluationresultsofxtcaequipmentforhepexperimentsatcern AT joosm evaluationresultsofxtcaequipmentforhepexperimentsatcern AT micos evaluationresultsofxtcaequipmentforhepexperimentsatcern AT vaseyf evaluationresultsofxtcaequipmentforhepexperimentsatcern AT vichoudisp evaluationresultsofxtcaequipmentforhepexperimentsatcern |