Cargando…

M11.3.1: Requirements for electron beam diagnostics

The all optical external injection scheme that we will use with two colliding laser pulses allows a way to stabilize the injection of electrons into the plasma wave, and to easily tune the energy of the output beam by changing the longitudinal position of the injection. The charge and relative energ...

Descripción completa

Detalles Bibliográficos
Autores principales: Malka, V, Faure, J
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1710457
_version_ 1780936706010120192
author Malka, V
Faure, J
author_facet Malka, V
Faure, J
author_sort Malka, V
collection CERN
description The all optical external injection scheme that we will use with two colliding laser pulses allows a way to stabilize the injection of electrons into the plasma wave, and to easily tune the energy of the output beam by changing the longitudinal position of the injection. The charge and relative energy spread are also controllable by tuning parameters such as the injection intensity and its polarization. We report here on the control of the ebeam parameters, on the e-beam parameters that will be used for the conception and design of the emittance meter and on the experimental arrangement on which emittance measurement experiments will be achieved.
format info:eu-repo/semantics/article
id cern-1710457
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-17104572019-09-30T06:29:59Z http://cds.cern.ch/record/1710457 eng Malka, V Faure, J M11.3.1: Requirements for electron beam diagnostics Accelerators and Storage Rings 11: Assessment of Novel Accelerator Concepts The all optical external injection scheme that we will use with two colliding laser pulses allows a way to stabilize the injection of electrons into the plasma wave, and to easily tune the energy of the output beam by changing the longitudinal position of the injection. The charge and relative energy spread are also controllable by tuning parameters such as the injection intensity and its polarization. We report here on the control of the ebeam parameters, on the e-beam parameters that will be used for the conception and design of the emittance meter and on the experimental arrangement on which emittance measurement experiments will be achieved. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1710457 2014
spellingShingle Accelerators and Storage Rings
11: Assessment of Novel Accelerator Concepts
Malka, V
Faure, J
M11.3.1: Requirements for electron beam diagnostics
title M11.3.1: Requirements for electron beam diagnostics
title_full M11.3.1: Requirements for electron beam diagnostics
title_fullStr M11.3.1: Requirements for electron beam diagnostics
title_full_unstemmed M11.3.1: Requirements for electron beam diagnostics
title_short M11.3.1: Requirements for electron beam diagnostics
title_sort m11.3.1: requirements for electron beam diagnostics
topic Accelerators and Storage Rings
11: Assessment of Novel Accelerator Concepts
url http://cds.cern.ch/record/1710457
http://cds.cern.ch/record/1710457
work_keys_str_mv AT malkav m1131requirementsforelectronbeamdiagnostics
AT faurej m1131requirementsforelectronbeamdiagnostics