Cargando…

Calibration and Monitoring of the Tile Calorimeter during LHC Run-I

The ATLAS hadronic calorimeter, named the Tile Calorimeter (TileCal), is a non-compensating sampling calorimeter comprised of steel and scintillating plastic tiles which are read-out by photomultiplier tubes (PMTs). The TileCal is regularly monitored and calibrated by several different calibration s...

Descripción completa

Detalles Bibliográficos
Autor principal: Darmora, S
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1711791
_version_ 1780936747337646080
author Darmora, S
author_facet Darmora, S
author_sort Darmora, S
collection CERN
description The ATLAS hadronic calorimeter, named the Tile Calorimeter (TileCal), is a non-compensating sampling calorimeter comprised of steel and scintillating plastic tiles which are read-out by photomultiplier tubes (PMTs). The TileCal is regularly monitored and calibrated by several different calibration systems: a Cs radioactive source that illuminates the scintillating tiles directly, a laser light system to directly test the PMT response, and a charge injection system (CIS) for the frontend electronics. These calibrations systems, in conjunction with data collected during protonproton collisions, provide extensive monitoring of the instrument and a means for equalizing the calorimeter response at each stage of signal propagation. Through the individual calibrations provided by these systems, we are able to achieve a precision of approximately 0.5-1.0% in the monitoring of the evolution of the response of the different components of TileCal. Analysis of the combined calibrations is used to measure the gain variance in the detector response. This contribution presents a brief description of the different TileCal calibration systems along with the latest results on their performance during the LHC Run I.
id cern-1711791
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-17117912022-08-10T20:19:33Zhttp://cds.cern.ch/record/1711791engDarmora, SCalibration and Monitoring of the Tile Calorimeter during LHC Run-IParticle Physics - ExperimentThe ATLAS hadronic calorimeter, named the Tile Calorimeter (TileCal), is a non-compensating sampling calorimeter comprised of steel and scintillating plastic tiles which are read-out by photomultiplier tubes (PMTs). The TileCal is regularly monitored and calibrated by several different calibration systems: a Cs radioactive source that illuminates the scintillating tiles directly, a laser light system to directly test the PMT response, and a charge injection system (CIS) for the frontend electronics. These calibrations systems, in conjunction with data collected during protonproton collisions, provide extensive monitoring of the instrument and a means for equalizing the calorimeter response at each stage of signal propagation. Through the individual calibrations provided by these systems, we are able to achieve a precision of approximately 0.5-1.0% in the monitoring of the evolution of the response of the different components of TileCal. Analysis of the combined calibrations is used to measure the gain variance in the detector response. This contribution presents a brief description of the different TileCal calibration systems along with the latest results on their performance during the LHC Run I.ATL-TILECAL-PROC-2014-016oai:cds.cern.ch:17117912014
spellingShingle Particle Physics - Experiment
Darmora, S
Calibration and Monitoring of the Tile Calorimeter during LHC Run-I
title Calibration and Monitoring of the Tile Calorimeter during LHC Run-I
title_full Calibration and Monitoring of the Tile Calorimeter during LHC Run-I
title_fullStr Calibration and Monitoring of the Tile Calorimeter during LHC Run-I
title_full_unstemmed Calibration and Monitoring of the Tile Calorimeter during LHC Run-I
title_short Calibration and Monitoring of the Tile Calorimeter during LHC Run-I
title_sort calibration and monitoring of the tile calorimeter during lhc run-i
topic Particle Physics - Experiment
url http://cds.cern.ch/record/1711791
work_keys_str_mv AT darmoras calibrationandmonitoringofthetilecalorimeterduringlhcruni