Cargando…
Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN
As part of the CERN LHC injector chain upgrade, LINAC4 [1, 2] will accelerate H- ions to 160 MeV, replacing the old 50 MeV proton linac. The ion source, the Low Energy Beam Transfer (LEBT) line, the 3 MeV Radio Frequency Quadrupole and the Medium Energy Beam Transfer (MEBT) line hosting a chopper, h...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1742119 |
_version_ | 1780942690040414208 |
---|---|
author | Zocca, F Allica Santamaria, J C Duraffourg, M Focker, G J Gerard, D Kolad, B Lenardon, F Ludwig, M Raich, U Roncarolo, F Sordet, M Tan, J Tassan-Viol, J Vuitton, C Feshenko, A |
author_facet | Zocca, F Allica Santamaria, J C Duraffourg, M Focker, G J Gerard, D Kolad, B Lenardon, F Ludwig, M Raich, U Roncarolo, F Sordet, M Tan, J Tassan-Viol, J Vuitton, C Feshenko, A |
author_sort | Zocca, F |
collection | CERN |
description | As part of the CERN LHC injector chain upgrade, LINAC4 [1, 2] will accelerate H- ions to 160 MeV, replacing the old 50 MeV proton linac. The ion source, the Low Energy Beam Transfer (LEBT) line, the 3 MeV Radio Frequency Quadrupole and the Medium Energy Beam Transfer (MEBT) line hosting a chopper, have been commissioned in the LINAC4 tunnel. Diagnostic devices are installed in the LEBT and MEBT line and in a movable diagnostics test bench which is temporarily added to the MEBT exit. The paper gives an overview of all the instruments used, including beam current transformers, beam position monitors, wire scanners and wire grids for transverse profile measurements, a longitudinal bunch shape monitor and a slit-and-grid emittance meter. The instrumentation performance is discussed and the measurement results that allowed characterizing the 3 MeV beam in the LINAC4 tunnel are summarized. |
id | cern-1742119 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-17421192022-08-17T13:31:19Zhttp://cds.cern.ch/record/1742119engZocca, FAllica Santamaria, J CDuraffourg, MFocker, G JGerard, DKolad, BLenardon, FLudwig, MRaich, URoncarolo, FSordet, MTan, JTassan-Viol, JVuitton, CFeshenko, ABeam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERNAccelerators and Storage RingsAs part of the CERN LHC injector chain upgrade, LINAC4 [1, 2] will accelerate H- ions to 160 MeV, replacing the old 50 MeV proton linac. The ion source, the Low Energy Beam Transfer (LEBT) line, the 3 MeV Radio Frequency Quadrupole and the Medium Energy Beam Transfer (MEBT) line hosting a chopper, have been commissioned in the LINAC4 tunnel. Diagnostic devices are installed in the LEBT and MEBT line and in a movable diagnostics test bench which is temporarily added to the MEBT exit. The paper gives an overview of all the instruments used, including beam current transformers, beam position monitors, wire scanners and wire grids for transverse profile measurements, a longitudinal bunch shape monitor and a slit-and-grid emittance meter. The instrumentation performance is discussed and the measurement results that allowed characterizing the 3 MeV beam in the LINAC4 tunnel are summarized.CERN-ACC-2014-0102oai:cds.cern.ch:17421192014 |
spellingShingle | Accelerators and Storage Rings Zocca, F Allica Santamaria, J C Duraffourg, M Focker, G J Gerard, D Kolad, B Lenardon, F Ludwig, M Raich, U Roncarolo, F Sordet, M Tan, J Tassan-Viol, J Vuitton, C Feshenko, A Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN |
title | Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN |
title_full | Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN |
title_fullStr | Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN |
title_full_unstemmed | Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN |
title_short | Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN |
title_sort | beam diagnostics measurements at 3 mev of the linac4 h- beam at cern |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1742119 |
work_keys_str_mv | AT zoccaf beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT allicasantamariajc beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT duraffourgm beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT fockergj beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT gerardd beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT koladb beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT lenardonf beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT ludwigm beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT raichu beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT roncarolof beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT sordetm beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT tanj beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT tassanviolj beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT vuittonc beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern AT feshenkoa beamdiagnosticsmeasurementsat3mevofthelinac4hbeamatcern |