At high intensities and at certain working points, an instability develops in the CERN PS Booster and large coherent transverse oscillations and beam loss occur [1]. The coherent oscillations and beam loss can be effectively controlled with the transverse damper system, but the origin of the instabi...

Descripción completa

Detalles Bibliográficos
Autores principales: McAteer, M, Carli, C, Forte, V, Rumolo, G, Tomás, R
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1742236
_version_ 1780942704265396224
author McAteer, M
Carli, C
Forte, V
Rumolo, G
Tomás, R
author_facet McAteer, M
Carli, C
Forte, V
Rumolo, G
Tomás, R
author_sort McAteer, M
collection CERN
description At high intensities and at certain working points, an instability develops in the CERN PS Booster and large coherent transverse oscillations and beam loss occur [1]. The coherent oscillations and beam loss can be effectively controlled with the transverse damper system, but the origin of the instability is not well understood. In preparation for nonlinear optics measurements in the PS Booster that will take place after CERN’s first Long Shutdown, trial measurements were made with the PSB’s new trajectory measurement system. The measurements gave some new insight into the nature of this transverse instability, and these observations are presented here.
id cern-1742236
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-17422362022-08-17T13:31:25Zhttp://cds.cern.ch/record/1742236engMcAteer, MCarli, CForte, VRumolo, GTomás, RObservation of coherent instability in the CERN PS BoosterAccelerators and Storage RingsAt high intensities and at certain working points, an instability develops in the CERN PS Booster and large coherent transverse oscillations and beam loss occur [1]. The coherent oscillations and beam loss can be effectively controlled with the transverse damper system, but the origin of the instability is not well understood. In preparation for nonlinear optics measurements in the PS Booster that will take place after CERN’s first Long Shutdown, trial measurements were made with the PSB’s new trajectory measurement system. The measurements gave some new insight into the nature of this transverse instability, and these observations are presented here.CERN-ACC-2014-0127oai:cds.cern.ch:17422362014
spellingShingle Accelerators and Storage Rings
McAteer, M
Carli, C
Forte, V
Rumolo, G
Tomás, R
Observation of coherent instability in the CERN PS Booster
title Observation of coherent instability in the CERN PS Booster
title_full Observation of coherent instability in the CERN PS Booster
title_fullStr Observation of coherent instability in the CERN PS Booster
title_full_unstemmed Observation of coherent instability in the CERN PS Booster
title_short Observation of coherent instability in the CERN PS Booster
title_sort observation of coherent instability in the cern ps booster
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1742236
work_keys_str_mv AT mcateerm observationofcoherentinstabilityinthecernpsbooster
AT carlic observationofcoherentinstabilityinthecernpsbooster
AT fortev observationofcoherentinstabilityinthecernpsbooster
AT rumolog observationofcoherentinstabilityinthecernpsbooster
AT tomasr observationofcoherentinstabilityinthecernpsbooster