The Control System for the CMS Strip Tracking Detector
The Tracker of the CMS silicon strip tracking detector covers a surface of 206 m2. 9648128 channels are available on 75376 APV front-end chips on 15232 modules, built of 24328 silicon sensors. The power supply of the detector modules is split up in 1944 power supplies with two low voltage for front...
Autores principales: | Fahrer, Manuel, Hartmann, Frank, Chen, Jie, Dierlamm, Alexander, Frey, Martin, Masetti, Lorenzo, Militaru, Otilia, Shah, Yousaf, Stringer, Robert, Tsirou, Andromachi |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1142/9789812819093_0127 http://cds.cern.ch/record/1742331 |