Cargando…
The Tracker–Muon Hardware Alignment System of CMS
The CMS detector has been instrumented with an optical and mechanical system that allows to perform a link between the central Tracker of the detector with the outer Barrel and Endcap muon chambers in order to relate the local alignments of these subsystems in a common reference frame. In this paper...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1142/9789812819093_0166 http://cds.cern.ch/record/1742909 |
_version_ | 1780942757079023616 |
---|---|
author | Martínez Rivero, Celso |
author_facet | Martínez Rivero, Celso |
author_sort | Martínez Rivero, Celso |
collection | CERN |
description | The CMS detector has been instrumented with an optical and mechanical system that allows to perform a link between the central Tracker of the detector with the outer Barrel and Endcap muon chambers in order to relate the local alignments of these subsystems in a common reference frame. In this paper the system will be described in detail and preliminary resuls of its operation under different magnetic conditions during the MTCC done in 2006 will be reported. |
id | cern-1742909 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-17429092019-09-30T06:29:59Zdoi:10.1142/9789812819093_0166http://cds.cern.ch/record/1742909engMartínez Rivero, CelsoThe Tracker–Muon Hardware Alignment System of CMSXXThe CMS detector has been instrumented with an optical and mechanical system that allows to perform a link between the central Tracker of the detector with the outer Barrel and Endcap muon chambers in order to relate the local alignments of these subsystems in a common reference frame. In this paper the system will be described in detail and preliminary resuls of its operation under different magnetic conditions during the MTCC done in 2006 will be reported.oai:cds.cern.ch:17429092008 |
spellingShingle | XX Martínez Rivero, Celso The Tracker–Muon Hardware Alignment System of CMS |
title | The Tracker–Muon Hardware Alignment System of CMS |
title_full | The Tracker–Muon Hardware Alignment System of CMS |
title_fullStr | The Tracker–Muon Hardware Alignment System of CMS |
title_full_unstemmed | The Tracker–Muon Hardware Alignment System of CMS |
title_short | The Tracker–Muon Hardware Alignment System of CMS |
title_sort | tracker–muon hardware alignment system of cms |
topic | XX |
url | https://dx.doi.org/10.1142/9789812819093_0166 http://cds.cern.ch/record/1742909 |
work_keys_str_mv | AT martinezriverocelso thetrackermuonhardwarealignmentsystemofcms AT martinezriverocelso trackermuonhardwarealignmentsystemofcms |