Cargando…

The Tracker–Muon Hardware Alignment System of CMS

The CMS detector has been instrumented with an optical and mechanical system that allows to perform a link between the central Tracker of the detector with the outer Barrel and Endcap muon chambers in order to relate the local alignments of these subsystems in a common reference frame. In this paper...

Descripción completa

Detalles Bibliográficos
Autor principal: Martínez Rivero, Celso
Lenguaje:eng
Publicado: 2008
Materias:
XX
Acceso en línea:https://dx.doi.org/10.1142/9789812819093_0166
http://cds.cern.ch/record/1742909
_version_ 1780942757079023616
author Martínez Rivero, Celso
author_facet Martínez Rivero, Celso
author_sort Martínez Rivero, Celso
collection CERN
description The CMS detector has been instrumented with an optical and mechanical system that allows to perform a link between the central Tracker of the detector with the outer Barrel and Endcap muon chambers in order to relate the local alignments of these subsystems in a common reference frame. In this paper the system will be described in detail and preliminary resuls of its operation under different magnetic conditions during the MTCC done in 2006 will be reported.
id cern-1742909
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-17429092019-09-30T06:29:59Zdoi:10.1142/9789812819093_0166http://cds.cern.ch/record/1742909engMartínez Rivero, CelsoThe Tracker–Muon Hardware Alignment System of CMSXXThe CMS detector has been instrumented with an optical and mechanical system that allows to perform a link between the central Tracker of the detector with the outer Barrel and Endcap muon chambers in order to relate the local alignments of these subsystems in a common reference frame. In this paper the system will be described in detail and preliminary resuls of its operation under different magnetic conditions during the MTCC done in 2006 will be reported.oai:cds.cern.ch:17429092008
spellingShingle XX
Martínez Rivero, Celso
The Tracker–Muon Hardware Alignment System of CMS
title The Tracker–Muon Hardware Alignment System of CMS
title_full The Tracker–Muon Hardware Alignment System of CMS
title_fullStr The Tracker–Muon Hardware Alignment System of CMS
title_full_unstemmed The Tracker–Muon Hardware Alignment System of CMS
title_short The Tracker–Muon Hardware Alignment System of CMS
title_sort tracker–muon hardware alignment system of cms
topic XX
url https://dx.doi.org/10.1142/9789812819093_0166
http://cds.cern.ch/record/1742909
work_keys_str_mv AT martinezriverocelso thetrackermuonhardwarealignmentsystemofcms
AT martinezriverocelso trackermuonhardwarealignmentsystemofcms