Cargando…

Update on beam loss monitoring at CTF3 for CLIC

The primary role of the beam loss monitoring (BLM) system for the compact linear collider (CLIC) study is to work within the machine protection system. Due to the size of the CLIC facility, a BLM that covers large distances along the beam line is highly desirable, in particular for the CLIC drive be...

Descripción completa

Detalles Bibliográficos
Autores principales: Devlin, L J, Welsch, C P, Effinger, E, Holzer, E B, del Busto, E N, Mallows, S, Branger, E
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1743067
_version_ 1780942769220485120
author Devlin, L J
Welsch, C P
Effinger, E
Holzer, E B
del Busto, E N
Mallows, S
Branger, E
author_facet Devlin, L J
Welsch, C P
Effinger, E
Holzer, E B
del Busto, E N
Mallows, S
Branger, E
author_sort Devlin, L J
collection CERN
description The primary role of the beam loss monitoring (BLM) system for the compact linear collider (CLIC) study is to work within the machine protection system. Due to the size of the CLIC facility, a BLM that covers large distances along the beam line is highly desirable, in particular for the CLIC drive beam decelerators, which would alternatively require some ~40,000 localised monitors. Therefore, an optical fibre BLM system is currently under investigation which can cover large sections of beam line at a time. A multimode fibre has been installed along the Test Beam Line at the CLIC test facility (CTF3) where the detection principle is based on the production of Cherenkov photons within the fibre resulting from beam loss and their subsequent transport along the fibre where they are then detected at the fibre ends using silicon photomultipliers. Several additional monitors including ACEMs, PEP-II and diamond detectors have also been installed. In this contribution the first results from the BLMs are presented, comparisons of the signals from each BLM are made and the possible achievable longitudinal resolution from the fibre BLM signal considering various loss patterns is discussed.
id cern-1743067
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2013
record_format invenio
spelling cern-17430672022-08-17T13:31:18Zhttp://cds.cern.ch/record/1743067engDevlin, L JWelsch, C PEffinger, EHolzer, E Bdel Busto, E NMallows, SBranger, EUpdate on beam loss monitoring at CTF3 for CLICAccelerators and Storage RingsThe primary role of the beam loss monitoring (BLM) system for the compact linear collider (CLIC) study is to work within the machine protection system. Due to the size of the CLIC facility, a BLM that covers large distances along the beam line is highly desirable, in particular for the CLIC drive beam decelerators, which would alternatively require some ~40,000 localised monitors. Therefore, an optical fibre BLM system is currently under investigation which can cover large sections of beam line at a time. A multimode fibre has been installed along the Test Beam Line at the CLIC test facility (CTF3) where the detection principle is based on the production of Cherenkov photons within the fibre resulting from beam loss and their subsequent transport along the fibre where they are then detected at the fibre ends using silicon photomultipliers. Several additional monitors including ACEMs, PEP-II and diamond detectors have also been installed. In this contribution the first results from the BLMs are presented, comparisons of the signals from each BLM are made and the possible achievable longitudinal resolution from the fibre BLM signal considering various loss patterns is discussed.oai:cds.cern.ch:17430672013
spellingShingle Accelerators and Storage Rings
Devlin, L J
Welsch, C P
Effinger, E
Holzer, E B
del Busto, E N
Mallows, S
Branger, E
Update on beam loss monitoring at CTF3 for CLIC
title Update on beam loss monitoring at CTF3 for CLIC
title_full Update on beam loss monitoring at CTF3 for CLIC
title_fullStr Update on beam loss monitoring at CTF3 for CLIC
title_full_unstemmed Update on beam loss monitoring at CTF3 for CLIC
title_short Update on beam loss monitoring at CTF3 for CLIC
title_sort update on beam loss monitoring at ctf3 for clic
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1743067
work_keys_str_mv AT devlinlj updateonbeamlossmonitoringatctf3forclic
AT welschcp updateonbeamlossmonitoringatctf3forclic
AT effingere updateonbeamlossmonitoringatctf3forclic
AT holzereb updateonbeamlossmonitoringatctf3forclic
AT delbustoen updateonbeamlossmonitoringatctf3forclic
AT mallowss updateonbeamlossmonitoringatctf3forclic
AT brangere updateonbeamlossmonitoringatctf3forclic