Cargando…
Performance tests during the IBL Stave Integration
In preparation of the ATLAS Pixel Insertable B-Layer integration, two detector components, so called staves, were mounted around the Beryllium ATLAS beam pipe and tested using production quality assurance measurements as well as dedicated data taking runs to validate a correct grounding and shieldin...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1752531 |
_version_ | 1780943184311877632 |
---|---|
author | Jentzsch, J |
author_facet | Jentzsch, J |
author_sort | Jentzsch, J |
collection | CERN |
description | In preparation of the ATLAS Pixel Insertable B-Layer integration, two detector components, so called staves, were mounted around the Beryllium ATLAS beam pipe and tested using production quality assurance measurements as well as dedicated data taking runs to validate a correct grounding and shielding schema. Each stave consists of 32 FE-I4 readout chips of ~ 2x2cm size which sums up to over 860k pixels per stave. The integration tests include verification that neither the silicon n-in-n nor the silicon 3D sensors were damaged by mechanical stress, and that their readout chips, including their bump bond and wire bond connections, did not suffered from the integration process. Evolution of the IBL performance during its integration will be discussed as well as its final performance before installation. |
id | cern-1752531 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-17525312019-09-30T06:29:59Zhttp://cds.cern.ch/record/1752531engJentzsch, JPerformance tests during the IBL Stave IntegrationParticle Physics - ExperimentIn preparation of the ATLAS Pixel Insertable B-Layer integration, two detector components, so called staves, were mounted around the Beryllium ATLAS beam pipe and tested using production quality assurance measurements as well as dedicated data taking runs to validate a correct grounding and shielding schema. Each stave consists of 32 FE-I4 readout chips of ~ 2x2cm size which sums up to over 860k pixels per stave. The integration tests include verification that neither the silicon n-in-n nor the silicon 3D sensors were damaged by mechanical stress, and that their readout chips, including their bump bond and wire bond connections, did not suffered from the integration process. Evolution of the IBL performance during its integration will be discussed as well as its final performance before installation.ATL-INDET-SLIDE-2014-565oai:cds.cern.ch:17525312014-08-29 |
spellingShingle | Particle Physics - Experiment Jentzsch, J Performance tests during the IBL Stave Integration |
title | Performance tests during the IBL Stave Integration |
title_full | Performance tests during the IBL Stave Integration |
title_fullStr | Performance tests during the IBL Stave Integration |
title_full_unstemmed | Performance tests during the IBL Stave Integration |
title_short | Performance tests during the IBL Stave Integration |
title_sort | performance tests during the ibl stave integration |
topic | Particle Physics - Experiment |
url | http://cds.cern.ch/record/1752531 |
work_keys_str_mv | AT jentzschj performancetestsduringtheiblstaveintegration |