Performance Tests during the IBL Stave Integration

In preparation of the ATLAS Pixel Insertable B-Layer integration, detector components, so called staves, were mounted around the Beryllium ATLAS beam pipe and tested using production quality assurance measurements as well as dedicated data taking runs to validate a correct grounding and shielding sc...

Descripción completa

Detalles Bibliográficos
Autor principal: Backhaus, M
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1753454
_version_ 1780943252908670976
author Backhaus, M
author_facet Backhaus, M
author_sort Backhaus, M
collection CERN
description In preparation of the ATLAS Pixel Insertable B-Layer integration, detector components, so called staves, were mounted around the Beryllium ATLAS beam pipe and tested using production quality assurance measurements as well as dedicated data taking runs to validate a correct grounding and shielding schema. Each stave consists of 32 FE-I4 readout chips of ~ 2x2cm size which sums up to over 860k pixels per stave. The integration tests include verification that neither the silicon n-in-n nor the silicon 3D sensors were damaged by mechanical stress, and that their readout chips, including their bump bond and wire bond connections, did not suffered from the integration process. Evolution of the IBL performance during its integration will be discussed as well as its final performance before installation.
id cern-1753454
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-17534542019-09-30T06:29:59Zhttp://cds.cern.ch/record/1753454engBackhaus, MPerformance Tests during the IBL Stave IntegrationParticle Physics - ExperimentIn preparation of the ATLAS Pixel Insertable B-Layer integration, detector components, so called staves, were mounted around the Beryllium ATLAS beam pipe and tested using production quality assurance measurements as well as dedicated data taking runs to validate a correct grounding and shielding schema. Each stave consists of 32 FE-I4 readout chips of ~ 2x2cm size which sums up to over 860k pixels per stave. The integration tests include verification that neither the silicon n-in-n nor the silicon 3D sensors were damaged by mechanical stress, and that their readout chips, including their bump bond and wire bond connections, did not suffered from the integration process. Evolution of the IBL performance during its integration will be discussed as well as its final performance before installation.ATL-INDET-SLIDE-2014-599oai:cds.cern.ch:17534542014-09-04
spellingShingle Particle Physics - Experiment
Backhaus, M
Performance Tests during the IBL Stave Integration
title Performance Tests during the IBL Stave Integration
title_full Performance Tests during the IBL Stave Integration
title_fullStr Performance Tests during the IBL Stave Integration
title_full_unstemmed Performance Tests during the IBL Stave Integration
title_short Performance Tests during the IBL Stave Integration
title_sort performance tests during the ibl stave integration
topic Particle Physics - Experiment
url http://cds.cern.ch/record/1753454
work_keys_str_mv AT backhausm performancetestsduringtheiblstaveintegration