Cargando…
An InGrid based Low Energy X-ray Detector
An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector allows for a topological background suppression along with a dete...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.3204/DESY-PROC-2014-03/krieger_christoph http://cds.cern.ch/record/1951763 |
_version_ | 1780944257336475648 |
---|---|
author | Krieger, Christoph Desch, Klaus Kaminski, Jochen Lupberger, Michael Vafeiadis, Theodoros |
author_facet | Krieger, Christoph Desch, Klaus Kaminski, Jochen Lupberger, Michael Vafeiadis, Theodoros |
author_sort | Krieger, Christoph |
collection | CERN |
description | An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector allows for a topological background suppression along with a detection threshold below $1\,\text{keV}$. Tests at the CAST Detector Lab show the detector's ability to detect X-ray photons down to an energy as low as $277\,\text{eV}$. The first background data taken after the installation at the CAST experiment underline the detector's performance with an average background rate of $5\times10^{-5}\,/\text{keV}/\text{cm}^2/\text{s}$ between 2 and $10\,\text{keV}$ when using a lead shielding. |
id | cern-1951763 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-19517632023-03-12T04:08:34Zdoi:10.3204/DESY-PROC-2014-03/krieger_christophhttp://cds.cern.ch/record/1951763engKrieger, ChristophDesch, KlausKaminski, JochenLupberger, MichaelVafeiadis, TheodorosAn InGrid based Low Energy X-ray DetectorDetectors and Experimental TechniquesAn X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector allows for a topological background suppression along with a detection threshold below $1\,\text{keV}$. Tests at the CAST Detector Lab show the detector's ability to detect X-ray photons down to an energy as low as $277\,\text{eV}$. The first background data taken after the installation at the CAST experiment underline the detector's performance with an average background rate of $5\times10^{-5}\,/\text{keV}/\text{cm}^2/\text{s}$ between 2 and $10\,\text{keV}$ when using a lead shielding.An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the \textbf{C}ERN \textbf{A}xion \textbf{S}olar \textbf{T}elescope. Due to its high granularity and spatial resolution this detector allows for a topological background suppression along with a detection threshold below $\SI{1}{\keV}$. Tests at the CAST Detector Lab show the detector's ability to detect X-ray photons down to an energy as low as $\SI{277}{\eV}$. The first background data taken after the installation at the CAST experiment underline the detector's performance with an average background rate of $\SI[per-mode=repeated-symbol]{5e-5}{\per\keV\per\centi\metre\squared\per\second}$ between $\num{2}$ and $\SI{10}{\keV}$ when using a lead shielding.An X-ray detector based on the combination of an integrated Micromegas stage with apixel chip has been built in order to be installed at the CERN Axion Solar Telescope.Due to its high granularity and spatial resolution this detector allows for a topologicalbackground suppression along with a detection threshold below 1 keV.Tests at the CAST Detector Lab show the detector’s ability to detect X-ray photons downto an energy as low as 277 eV. The first background data taken after the installation atthe CAST experiment underline the detector’s performance with an average backgroundrate of 5 × 10$^{−5}$ /keV/cm$^2$/s between 2 and 10 keV when using a lead shielding.An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector allows for a topological background suppression along with a detection threshold below $1\,\text{keV}$. Tests at the CAST Detector Lab show the detector's ability to detect X-ray photons down to an energy as low as $277\,\text{eV}$. The first background data taken after the installation at the CAST experiment underline the detector's performance with an average background rate of $5\times10^{-5}\,/\text{keV}/\text{cm}^2/\text{s}$ between 2 and $10\,\text{keV}$ when using a lead shielding.arXiv:1410.0264oai:cds.cern.ch:19517632014-10-01 |
spellingShingle | Detectors and Experimental Techniques Krieger, Christoph Desch, Klaus Kaminski, Jochen Lupberger, Michael Vafeiadis, Theodoros An InGrid based Low Energy X-ray Detector |
title | An InGrid based Low Energy X-ray Detector |
title_full | An InGrid based Low Energy X-ray Detector |
title_fullStr | An InGrid based Low Energy X-ray Detector |
title_full_unstemmed | An InGrid based Low Energy X-ray Detector |
title_short | An InGrid based Low Energy X-ray Detector |
title_sort | ingrid based low energy x-ray detector |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.3204/DESY-PROC-2014-03/krieger_christoph http://cds.cern.ch/record/1951763 |
work_keys_str_mv | AT kriegerchristoph aningridbasedlowenergyxraydetector AT deschklaus aningridbasedlowenergyxraydetector AT kaminskijochen aningridbasedlowenergyxraydetector AT lupbergermichael aningridbasedlowenergyxraydetector AT vafeiadistheodoros aningridbasedlowenergyxraydetector AT kriegerchristoph ingridbasedlowenergyxraydetector AT deschklaus ingridbasedlowenergyxraydetector AT kaminskijochen ingridbasedlowenergyxraydetector AT lupbergermichael ingridbasedlowenergyxraydetector AT vafeiadistheodoros ingridbasedlowenergyxraydetector |