Cargando…

On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber

A new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sam- pling device where the ammonia was transferred to the liq- uid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by...

Descripción completa

Detalles Bibliográficos
Autores principales: Bianchi, F, Dommen, J, Mathot, S, Baltensperger, U
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:https://dx.doi.org/10.5194/amt-5-1719-2012
http://cds.cern.ch/record/1972012
_version_ 1780944864159989760
author Bianchi, F
Dommen, J
Mathot, S
Baltensperger, U
author_facet Bianchi, F
Dommen, J
Mathot, S
Baltensperger, U
author_sort Bianchi, F
collection CERN
description A new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sam- pling device where the ammonia was transferred to the liq- uid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by long pathlength absorption spectrophotom- etry using the Berthelot reaction with phenol and hypochlo- rite as reagents. The measurements were made during the CLOUD3 campaign at CERN where the influence of ammo- nia on the nucleation rate was studied. At stable conditions the detection limit reached with this instrument was 35 pptv (air flow rate of 2 l min − 1 , liquid flow rate of 0.3 ml min − 1 ), although occasionally the instrument was affected by back- ground problems. The range of mixing ratios during this campaign was varied from the background contamination ( < 35 pptv) up to around 2 ppbv. The measured ammonia concentration was correlated with the rate of ammonia in- jected into the chamber, but with a response time of several hours due to the high tendency of ammonia to adsorb to or to desorb from surfaces. Since it was found that ammonia strongly increases the nucleation rate already at the lowest measured concentration, future work will focus on further decreasing the detection limit of the instrument.
id cern-1972012
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-19720122019-09-30T06:29:59Zdoi:10.5194/amt-5-1719-2012http://cds.cern.ch/record/1972012engBianchi, FDommen, JMathot, SBaltensperger, UOn-line determination of ammonia at low pptv mixing ratios in the CLOUD chamberChemical Physics and ChemistryA new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sam- pling device where the ammonia was transferred to the liq- uid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by long pathlength absorption spectrophotom- etry using the Berthelot reaction with phenol and hypochlo- rite as reagents. The measurements were made during the CLOUD3 campaign at CERN where the influence of ammo- nia on the nucleation rate was studied. At stable conditions the detection limit reached with this instrument was 35 pptv (air flow rate of 2 l min − 1 , liquid flow rate of 0.3 ml min − 1 ), although occasionally the instrument was affected by back- ground problems. The range of mixing ratios during this campaign was varied from the background contamination ( < 35 pptv) up to around 2 ppbv. The measured ammonia concentration was correlated with the rate of ammonia in- jected into the chamber, but with a response time of several hours due to the high tendency of ammonia to adsorb to or to desorb from surfaces. Since it was found that ammonia strongly increases the nucleation rate already at the lowest measured concentration, future work will focus on further decreasing the detection limit of the instrument.oai:cds.cern.ch:19720122012
spellingShingle Chemical Physics and Chemistry
Bianchi, F
Dommen, J
Mathot, S
Baltensperger, U
On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber
title On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber
title_full On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber
title_fullStr On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber
title_full_unstemmed On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber
title_short On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber
title_sort on-line determination of ammonia at low pptv mixing ratios in the cloud chamber
topic Chemical Physics and Chemistry
url https://dx.doi.org/10.5194/amt-5-1719-2012
http://cds.cern.ch/record/1972012
work_keys_str_mv AT bianchif onlinedeterminationofammoniaatlowpptvmixingratiosinthecloudchamber
AT dommenj onlinedeterminationofammoniaatlowpptvmixingratiosinthecloudchamber
AT mathots onlinedeterminationofammoniaatlowpptvmixingratiosinthecloudchamber
AT baltenspergeru onlinedeterminationofammoniaatlowpptvmixingratiosinthecloudchamber