Cargando…
On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber
A new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sam- pling device where the ammonia was transferred to the liq- uid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5194/amt-5-1719-2012 http://cds.cern.ch/record/1972012 |
_version_ | 1780944864159989760 |
---|---|
author | Bianchi, F Dommen, J Mathot, S Baltensperger, U |
author_facet | Bianchi, F Dommen, J Mathot, S Baltensperger, U |
author_sort | Bianchi, F |
collection | CERN |
description | A new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sam- pling device where the ammonia was transferred to the liq- uid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by long pathlength absorption spectrophotom- etry using the Berthelot reaction with phenol and hypochlo- rite as reagents. The measurements were made during the CLOUD3 campaign at CERN where the influence of ammo- nia on the nucleation rate was studied. At stable conditions the detection limit reached with this instrument was 35 pptv (air flow rate of 2 l min − 1 , liquid flow rate of 0.3 ml min − 1 ), although occasionally the instrument was affected by back- ground problems. The range of mixing ratios during this campaign was varied from the background contamination ( < 35 pptv) up to around 2 ppbv. The measured ammonia concentration was correlated with the rate of ammonia in- jected into the chamber, but with a response time of several hours due to the high tendency of ammonia to adsorb to or to desorb from surfaces. Since it was found that ammonia strongly increases the nucleation rate already at the lowest measured concentration, future work will focus on further decreasing the detection limit of the instrument. |
id | cern-1972012 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-19720122019-09-30T06:29:59Zdoi:10.5194/amt-5-1719-2012http://cds.cern.ch/record/1972012engBianchi, FDommen, JMathot, SBaltensperger, UOn-line determination of ammonia at low pptv mixing ratios in the CLOUD chamberChemical Physics and ChemistryA new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sam- pling device where the ammonia was transferred to the liq- uid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by long pathlength absorption spectrophotom- etry using the Berthelot reaction with phenol and hypochlo- rite as reagents. The measurements were made during the CLOUD3 campaign at CERN where the influence of ammo- nia on the nucleation rate was studied. At stable conditions the detection limit reached with this instrument was 35 pptv (air flow rate of 2 l min − 1 , liquid flow rate of 0.3 ml min − 1 ), although occasionally the instrument was affected by back- ground problems. The range of mixing ratios during this campaign was varied from the background contamination ( < 35 pptv) up to around 2 ppbv. The measured ammonia concentration was correlated with the rate of ammonia in- jected into the chamber, but with a response time of several hours due to the high tendency of ammonia to adsorb to or to desorb from surfaces. Since it was found that ammonia strongly increases the nucleation rate already at the lowest measured concentration, future work will focus on further decreasing the detection limit of the instrument.oai:cds.cern.ch:19720122012 |
spellingShingle | Chemical Physics and Chemistry Bianchi, F Dommen, J Mathot, S Baltensperger, U On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber |
title | On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber |
title_full | On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber |
title_fullStr | On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber |
title_full_unstemmed | On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber |
title_short | On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber |
title_sort | on-line determination of ammonia at low pptv mixing ratios in the cloud chamber |
topic | Chemical Physics and Chemistry |
url | https://dx.doi.org/10.5194/amt-5-1719-2012 http://cds.cern.ch/record/1972012 |
work_keys_str_mv | AT bianchif onlinedeterminationofammoniaatlowpptvmixingratiosinthecloudchamber AT dommenj onlinedeterminationofammoniaatlowpptvmixingratiosinthecloudchamber AT mathots onlinedeterminationofammoniaatlowpptvmixingratiosinthecloudchamber AT baltenspergeru onlinedeterminationofammoniaatlowpptvmixingratiosinthecloudchamber |