Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes
We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a f...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1972436 |
_version_ | 1780944878568472576 |
---|---|
author | Cantero, E D Andreazza, W Bravin, E Sosa, A |
author_facet | Cantero, E D Andreazza, W Bravin, E Sosa, A |
author_sort | Cantero, E D |
collection | CERN |
description | We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing. |
id | cern-1972436 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-19724362023-08-04T20:24:59Zhttp://cds.cern.ch/record/1972436engCantero, E DAndreazza, WBravin, ESosa, AAcceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxesAccelerators and Storage RingsWe performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing.CERN-ACC-Note-2014-0099oai:cds.cern.ch:19724362014-11-27 |
spellingShingle | Accelerators and Storage Rings Cantero, E D Andreazza, W Bravin, E Sosa, A Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes |
title | Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes |
title_full | Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes |
title_fullStr | Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes |
title_full_unstemmed | Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes |
title_short | Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes |
title_sort | acceptance test for the linear motion actuator for the scanning slit of the hie-isolde short diagnostic boxes |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1972436 |
work_keys_str_mv | AT canteroed acceptancetestforthelinearmotionactuatorforthescanningslitofthehieisoldeshortdiagnosticboxes AT andreazzaw acceptancetestforthelinearmotionactuatorforthescanningslitofthehieisoldeshortdiagnosticboxes AT bravine acceptancetestforthelinearmotionactuatorforthescanningslitofthehieisoldeshortdiagnosticboxes AT sosaa acceptancetestforthelinearmotionactuatorforthescanningslitofthehieisoldeshortdiagnosticboxes |