Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes

We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a f...

Descripción completa

Detalles Bibliográficos
Autores principales: Cantero, E D, Andreazza, W, Bravin, E, Sosa, A
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1972436
_version_ 1780944878568472576
author Cantero, E D
Andreazza, W
Bravin, E
Sosa, A
author_facet Cantero, E D
Andreazza, W
Bravin, E
Sosa, A
author_sort Cantero, E D
collection CERN
description We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing.
id cern-1972436
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-19724362023-08-04T20:24:59Zhttp://cds.cern.ch/record/1972436engCantero, E DAndreazza, WBravin, ESosa, AAcceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxesAccelerators and Storage RingsWe performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing.CERN-ACC-Note-2014-0099oai:cds.cern.ch:19724362014-11-27
spellingShingle Accelerators and Storage Rings
Cantero, E D
Andreazza, W
Bravin, E
Sosa, A
Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes
title Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes
title_full Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes
title_fullStr Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes
title_full_unstemmed Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes
title_short Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes
title_sort acceptance test for the linear motion actuator for the scanning slit of the hie-isolde short diagnostic boxes
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1972436
work_keys_str_mv AT canteroed acceptancetestforthelinearmotionactuatorforthescanningslitofthehieisoldeshortdiagnosticboxes
AT andreazzaw acceptancetestforthelinearmotionactuatorforthescanningslitofthehieisoldeshortdiagnosticboxes
AT bravine acceptancetestforthelinearmotionactuatorforthescanningslitofthehieisoldeshortdiagnosticboxes
AT sosaa acceptancetestforthelinearmotionactuatorforthescanningslitofthehieisoldeshortdiagnosticboxes