Cargando…

Transverse beam profile measurements with slit scanner and Faraday cup at REX-ISOLDE

The transverse profiles for the HIE-ISOLDE beams will be measured using a system composed of a scanning slit and a Faraday cup. A validation test of the proposed device was performed using the REX-ISOLDE stable beam and a prototype diagnostic box designed for HIE-ISOLDE. The slit used for this test...

Descripción completa

Detalles Bibliográficos
Autores principales: Cantero, E D, Bravin, E, Lanaia, D, Sosa, A, Voulot, D
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1972437
_version_ 1780944878788673536
author Cantero, E D
Bravin, E
Lanaia, D
Sosa, A
Voulot, D
author_facet Cantero, E D
Bravin, E
Lanaia, D
Sosa, A
Voulot, D
author_sort Cantero, E D
collection CERN
description The transverse profiles for the HIE-ISOLDE beams will be measured using a system composed of a scanning slit and a Faraday cup. A validation test of the proposed device was performed using the REX-ISOLDE stable beam and a prototype diagnostic box designed for HIE-ISOLDE. The slit used for this test was very thin (0.2 mm width), but still fairly good profiles could be obtained for beams with total current of around 20 pA (typical beam intensity during normal set-up procedures for REX-ISOLDE).
id cern-1972437
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-19724372023-08-04T20:24:59Zhttp://cds.cern.ch/record/1972437engCantero, E DBravin, ELanaia, DSosa, AVoulot, DTransverse beam profile measurements with slit scanner and Faraday cup at REX-ISOLDEAccelerators and Storage RingsThe transverse profiles for the HIE-ISOLDE beams will be measured using a system composed of a scanning slit and a Faraday cup. A validation test of the proposed device was performed using the REX-ISOLDE stable beam and a prototype diagnostic box designed for HIE-ISOLDE. The slit used for this test was very thin (0.2 mm width), but still fairly good profiles could be obtained for beams with total current of around 20 pA (typical beam intensity during normal set-up procedures for REX-ISOLDE).CERN-ACC-Note-2014-0100oai:cds.cern.ch:19724372014-11-27
spellingShingle Accelerators and Storage Rings
Cantero, E D
Bravin, E
Lanaia, D
Sosa, A
Voulot, D
Transverse beam profile measurements with slit scanner and Faraday cup at REX-ISOLDE
title Transverse beam profile measurements with slit scanner and Faraday cup at REX-ISOLDE
title_full Transverse beam profile measurements with slit scanner and Faraday cup at REX-ISOLDE
title_fullStr Transverse beam profile measurements with slit scanner and Faraday cup at REX-ISOLDE
title_full_unstemmed Transverse beam profile measurements with slit scanner and Faraday cup at REX-ISOLDE
title_short Transverse beam profile measurements with slit scanner and Faraday cup at REX-ISOLDE
title_sort transverse beam profile measurements with slit scanner and faraday cup at rex-isolde
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1972437
work_keys_str_mv AT canteroed transversebeamprofilemeasurementswithslitscannerandfaradaycupatrexisolde
AT bravine transversebeamprofilemeasurementswithslitscannerandfaradaycupatrexisolde
AT lanaiad transversebeamprofilemeasurementswithslitscannerandfaradaycupatrexisolde
AT sosaa transversebeamprofilemeasurementswithslitscannerandfaradaycupatrexisolde
AT voulotd transversebeamprofilemeasurementswithslitscannerandfaradaycupatrexisolde