Cargando…

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

An accurate laboratory characterization of beam intensity monitors requires a reliable integration of analogue signals simulating beam pulses. This poses particular difficulties when a high integration resolution is necessary for short pulses. However, the recent availability of fast 12-bit oscillos...

Descripción completa

Detalles Bibliográficos
Autores principales: Gasior, M, Krupa, M
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/1972449
_version_ 1780944880487366656
author Gasior, M
Krupa, M
author_facet Gasior, M
Krupa, M
author_sort Gasior, M
collection CERN
description An accurate laboratory characterization of beam intensity monitors requires a reliable integration of analogue signals simulating beam pulses. This poses particular difficulties when a high integration resolution is necessary for short pulses. However, the recent availability of fast 12-bit oscilloscopes now makes it possible to perform precise digital integration of nanosecond pulses using such instruments. This paper describes the methods and results of laboratory charge measurements performed at CERN using a 12-bit oscilloscope with 1 GHz analogue bandwidth and 2.5 GS/s sampling.
id cern-1972449
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-19724492019-09-30T06:29:59Zhttp://cds.cern.ch/record/1972449engGasior, MKrupa, MPrecise Digital Integration of Fast Analogue Signals using a 12-bit OscilloscopeAccelerators and Storage RingsAccelerators and Storage RingsAn accurate laboratory characterization of beam intensity monitors requires a reliable integration of analogue signals simulating beam pulses. This poses particular difficulties when a high integration resolution is necessary for short pulses. However, the recent availability of fast 12-bit oscilloscopes now makes it possible to perform precise digital integration of nanosecond pulses using such instruments. This paper describes the methods and results of laboratory charge measurements performed at CERN using a 12-bit oscilloscope with 1 GHz analogue bandwidth and 2.5 GS/s sampling.CERN-BE-2014-002oai:cds.cern.ch:19724492014-09-01
spellingShingle Accelerators and Storage Rings
Accelerators and Storage Rings
Gasior, M
Krupa, M
Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope
title Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope
title_full Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope
title_fullStr Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope
title_full_unstemmed Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope
title_short Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope
title_sort precise digital integration of fast analogue signals using a 12-bit oscilloscope
topic Accelerators and Storage Rings
Accelerators and Storage Rings
url http://cds.cern.ch/record/1972449
work_keys_str_mv AT gasiorm precisedigitalintegrationoffastanaloguesignalsusinga12bitoscilloscope
AT krupam precisedigitalintegrationoffastanaloguesignalsusinga12bitoscilloscope