Cargando…
Machine Protection System response in 2011
The performance of the machine protection system during the 2011 run is summarized in this paper. Following an analysis of the beam dump causes in comparison to the previous 2010 run, special emphasis will be given to analyse events which risked to exposed parts of the machine to damage. Further imp...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1975491 |
_version_ | 1780945086742265856 |
---|---|
author | Zerlauth, M Schmidt, R Wenninger, J |
author_facet | Zerlauth, M Schmidt, R Wenninger, J |
author_sort | Zerlauth, M |
collection | CERN |
description | The performance of the machine protection system during the 2011 run is summarized in this paper. Following an analysis of the beam dump causes in comparison to the previous 2010 run, special emphasis will be given to analyse events which risked to exposed parts of the machine to damage. Further improvements and mitigations of potential holes in the protection systems as well as in the change management will be evaluated along with their impact on the 2012 run. The role of the restricted Machine Protection Panel ( rMPP ) during the various operational phases such as commissioning, the intensity ramp up and Machine Developments is being discussed. |
id | cern-1975491 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-19754912022-08-10T20:23:23Zhttp://cds.cern.ch/record/1975491engZerlauth, MSchmidt, RWenninger, JMachine Protection System response in 2011Accelerators and Storage RingsThe performance of the machine protection system during the 2011 run is summarized in this paper. Following an analysis of the beam dump causes in comparison to the previous 2010 run, special emphasis will be given to analyse events which risked to exposed parts of the machine to damage. Further improvements and mitigations of potential holes in the protection systems as well as in the change management will be evaluated along with their impact on the 2012 run. The role of the restricted Machine Protection Panel ( rMPP ) during the various operational phases such as commissioning, the intensity ramp up and Machine Developments is being discussed.oai:cds.cern.ch:19754912012 |
spellingShingle | Accelerators and Storage Rings Zerlauth, M Schmidt, R Wenninger, J Machine Protection System response in 2011 |
title | Machine Protection System response in 2011 |
title_full | Machine Protection System response in 2011 |
title_fullStr | Machine Protection System response in 2011 |
title_full_unstemmed | Machine Protection System response in 2011 |
title_short | Machine Protection System response in 2011 |
title_sort | machine protection system response in 2011 |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1975491 |
work_keys_str_mv | AT zerlauthm machineprotectionsystemresponsein2011 AT schmidtr machineprotectionsystemresponsein2011 AT wenningerj machineprotectionsystemresponsein2011 |