Kinematical analysis with the Emulsion Cloud Chamber in the OPERA experiment
The OPERA experiment aims at measuring for the first time neutrino oscil- lation in appearance mode through the detection of ni-tau in an almost pure niμ beam produced at CERN SPS (CNGS), 730 km far from the detector. The ni-tau appearance signal is identified through the measurement of the decay da...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2010
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2010-003.208 http://cds.cern.ch/record/1977149 |
Sumario: | The OPERA experiment aims at measuring for the first time neutrino oscil- lation in appearance mode through the detection of ni-tau in an almost pure niμ beam produced at CERN SPS (CNGS), 730 km far from the detector. The ni-tau appearance signal is identified through the measurement of the decay daughter particles of the " lepton produced in CC ni-tau interactions. Since the short-lived " particle has, at the energy of the beam, an average decay length shorter than a 1 mm, a micrometric detection resolution is needed. The OPERA appara- tus is hybrid, using nuclear emulsion as high precision tracker and electronic detectors for the time stamp, event localization in the target and muon recon- struction. The Emulsion Cloud Chamber technique fulfils the requirement of a microscopic resolution together with a large target mass. The kinematical analysis allowed by this technique is described. |
---|