Efficient Parametric Identification Method for High Voltage Pulse Transformers
This paper presents a new identification method for a pulse transformer equivalent circuit. It is based on an analytical approximation of the frequency-domain impedance data derived from a no-load test with open-circuited secondary winding and only requires measurements of primary current and voltag...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1977422 |
_version_ | 1780945172379467776 |
---|---|
author | Aguglia, D Candolfi, S Viarouge, P Cros, J |
author_facet | Aguglia, D Candolfi, S Viarouge, P Cros, J |
author_sort | Aguglia, D |
collection | CERN |
description | This paper presents a new identification method for a pulse transformer equivalent circuit. It is based on an analytical approximation of the frequency-domain impedance data derived from a no-load test with open-circuited secondary winding and only requires measurements of primary current and voltage without phase data. Compared with time consuming and complex methods based on off-line non-linear identification procedures, this simple method also gives an estimation of the error on the identified parameters. The method is validated on an existing pulse transformer. |
id | cern-1977422 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-19774222019-09-30T06:29:59Zhttp://cds.cern.ch/record/1977422engAguglia, DCandolfi, SViarouge, PCros, JEfficient Parametric Identification Method for High Voltage Pulse TransformersAccelerators and Storage RingsThis paper presents a new identification method for a pulse transformer equivalent circuit. It is based on an analytical approximation of the frequency-domain impedance data derived from a no-load test with open-circuited secondary winding and only requires measurements of primary current and voltage without phase data. Compared with time consuming and complex methods based on off-line non-linear identification procedures, this simple method also gives an estimation of the error on the identified parameters. The method is validated on an existing pulse transformer.CERN-ACC-2014-0347oai:cds.cern.ch:19774222014-12-17 |
spellingShingle | Accelerators and Storage Rings Aguglia, D Candolfi, S Viarouge, P Cros, J Efficient Parametric Identification Method for High Voltage Pulse Transformers |
title | Efficient Parametric Identification Method for High Voltage Pulse Transformers |
title_full | Efficient Parametric Identification Method for High Voltage Pulse Transformers |
title_fullStr | Efficient Parametric Identification Method for High Voltage Pulse Transformers |
title_full_unstemmed | Efficient Parametric Identification Method for High Voltage Pulse Transformers |
title_short | Efficient Parametric Identification Method for High Voltage Pulse Transformers |
title_sort | efficient parametric identification method for high voltage pulse transformers |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1977422 |
work_keys_str_mv | AT agugliad efficientparametricidentificationmethodforhighvoltagepulsetransformers AT candolfis efficientparametricidentificationmethodforhighvoltagepulsetransformers AT viarougep efficientparametricidentificationmethodforhighvoltagepulsetransformers AT crosj efficientparametricidentificationmethodforhighvoltagepulsetransformers |