Cargando…

The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC

The High Luminosity LHC (HL-LHC) will provide unprecedented instantaneous and integrated luminosity. The lead tungstate crystals forming the barrel part of the CMS Electromagnetic Calorimeter (ECAL) will still perform well, even after the expected 3000fb-1 at the end of HL-LHC. The avalanche photodi...

Descripción completa

Detalles Bibliográficos
Autor principal: Obertino, Margherita Maria
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:https://dx.doi.org/10.1109/NSSMIC.2014.7431151
http://cds.cern.ch/record/1979594
_version_ 1780945203512737792
author Obertino, Margherita Maria
author_facet Obertino, Margherita Maria
author_sort Obertino, Margherita Maria
collection CERN
description The High Luminosity LHC (HL-LHC) will provide unprecedented instantaneous and integrated luminosity. The lead tungstate crystals forming the barrel part of the CMS Electromagnetic Calorimeter (ECAL) will still perform well, even after the expected 3000fb-1 at the end of HL-LHC. The avalanche photodiodes (APDs) used to detect the scintillation light have recently been exposed to the levels of radiation expected at the end of HL-LHC. Although they will continue to be operational, there will be some increase in noise due to radiation-induced dark-currents. Triggering CMS with ~140 pileup events necessitates a change of the front-end electronics. New developments in high-speed optical links will allow single-crystal readout at 40 MHz. This will provide maximum flexibility and enhanced triggering possibilities when used in conjunction with upgraded off-detector processors. The very-front-end system will also be upgraded, to provide improved rejection of anomalous signals in the APDs as well as to mitigate the increase in APD noise. We are also considering lowering the ECAL barrel operating temperature from 18 degrees C to about 8-10 degrees C, in order to increase the scintillation light output and reduce the APD dark current.
id cern-1979594
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-19795942019-09-30T06:29:59Zdoi:10.1109/NSSMIC.2014.7431151http://cds.cern.ch/record/1979594engObertino, Margherita MariaThe CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHCDetectors and Experimental TechniquesThe High Luminosity LHC (HL-LHC) will provide unprecedented instantaneous and integrated luminosity. The lead tungstate crystals forming the barrel part of the CMS Electromagnetic Calorimeter (ECAL) will still perform well, even after the expected 3000fb-1 at the end of HL-LHC. The avalanche photodiodes (APDs) used to detect the scintillation light have recently been exposed to the levels of radiation expected at the end of HL-LHC. Although they will continue to be operational, there will be some increase in noise due to radiation-induced dark-currents. Triggering CMS with ~140 pileup events necessitates a change of the front-end electronics. New developments in high-speed optical links will allow single-crystal readout at 40 MHz. This will provide maximum flexibility and enhanced triggering possibilities when used in conjunction with upgraded off-detector processors. The very-front-end system will also be upgraded, to provide improved rejection of anomalous signals in the APDs as well as to mitigate the increase in APD noise. We are also considering lowering the ECAL barrel operating temperature from 18 degrees C to about 8-10 degrees C, in order to increase the scintillation light output and reduce the APD dark current.CMS-CR-2014-414oai:cds.cern.ch:19795942014-11-21
spellingShingle Detectors and Experimental Techniques
Obertino, Margherita Maria
The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
title The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
title_full The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
title_fullStr The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
title_full_unstemmed The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
title_short The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
title_sort cms electromagnetic calorimeter barrel upgrade for high-luminosity lhc
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/NSSMIC.2014.7431151
http://cds.cern.ch/record/1979594
work_keys_str_mv AT obertinomargheritamaria thecmselectromagneticcalorimeterbarrelupgradeforhighluminositylhc
AT obertinomargheritamaria cmselectromagneticcalorimeterbarrelupgradeforhighluminositylhc