LumiCal alignment system - Status report
The paper describes the status of the laser-based alignment-system for the luminosity detector, LumiCal, taking into considerations the conditions of the International Large Detector in the International Linear Collider project. The design of the system comprises two parts: the first one containing...
Autores principales: | , , , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1989445 |
_version_ | 1780945665229062144 |
---|---|
author | Daniluk, W. Krupa, B. Lesiak, T. Moszczyński, A. Pawlik, B. Wojtoń, T. Zawiejski, L. |
author_facet | Daniluk, W. Krupa, B. Lesiak, T. Moszczyński, A. Pawlik, B. Wojtoń, T. Zawiejski, L. |
author_sort | Daniluk, W. |
collection | CERN |
description | The paper describes the status of the laser-based alignment-system for the luminosity detector, LumiCal, taking into considerations the conditions of the International Large Detector in the International Linear Collider project. The design of the system comprises two parts: the first one containing semi-transparent silicon sensors used to deliver simultaneous position measurements in the X,Y directions of the monitored object, and the second one in which the interferometric technique, i.e. the Frequency Scanning Interferometry (FSI), is proposed. Two laboratory prototypes for both components of the system were built and the preliminary measurements of the DUT displacements demonstrated their utility in the design of the final alignment system. The alignment of the LumiCal detector will allow us to monitor the detector displacements and possible deformations in its internal structure. Lack of information of the displacements will introduce a systematic effect which will have an impact on the accuracy of the final luminosity calculations. According to the requirements of the comprehensive research program prepared for the ILC, such a luminosity uncertainty should not be worse than 10^-3. |
format | info:eu-repo/semantics/article |
id | cern-1989445 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | cern-19894452019-09-30T06:29:59Z http://cds.cern.ch/record/1989445 eng Daniluk, W. Krupa, B. Lesiak, T. Moszczyński, A. Pawlik, B. Wojtoń, T. Zawiejski, L. LumiCal alignment system - Status report Detectors and Experimental Techniques 9: Advanced infrastructures for detector R&D 9.5:Highly Granular Calorimetry The paper describes the status of the laser-based alignment-system for the luminosity detector, LumiCal, taking into considerations the conditions of the International Large Detector in the International Linear Collider project. The design of the system comprises two parts: the first one containing semi-transparent silicon sensors used to deliver simultaneous position measurements in the X,Y directions of the monitored object, and the second one in which the interferometric technique, i.e. the Frequency Scanning Interferometry (FSI), is proposed. Two laboratory prototypes for both components of the system were built and the preliminary measurements of the DUT displacements demonstrated their utility in the design of the final alignment system. The alignment of the LumiCal detector will allow us to monitor the detector displacements and possible deformations in its internal structure. Lack of information of the displacements will introduce a systematic effect which will have an impact on the accuracy of the final luminosity calculations. According to the requirements of the comprehensive research program prepared for the ILC, such a luminosity uncertainty should not be worse than 10^-3. info:eu-repo/grantAgreement/EC/FP7/262025 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1989445 2015 |
spellingShingle | Detectors and Experimental Techniques 9: Advanced infrastructures for detector R&D 9.5:Highly Granular Calorimetry Daniluk, W. Krupa, B. Lesiak, T. Moszczyński, A. Pawlik, B. Wojtoń, T. Zawiejski, L. LumiCal alignment system - Status report |
title | LumiCal alignment system - Status report |
title_full | LumiCal alignment system - Status report |
title_fullStr | LumiCal alignment system - Status report |
title_full_unstemmed | LumiCal alignment system - Status report |
title_short | LumiCal alignment system - Status report |
title_sort | lumical alignment system - status report |
topic | Detectors and Experimental Techniques 9: Advanced infrastructures for detector R&D 9.5:Highly Granular Calorimetry |
url | http://cds.cern.ch/record/1989445 http://cds.cern.ch/record/1989445 |
work_keys_str_mv | AT danilukw lumicalalignmentsystemstatusreport AT krupab lumicalalignmentsystemstatusreport AT lesiakt lumicalalignmentsystemstatusreport AT moszczynskia lumicalalignmentsystemstatusreport AT pawlikb lumicalalignmentsystemstatusreport AT wojtont lumicalalignmentsystemstatusreport AT zawiejskil lumicalalignmentsystemstatusreport |