Cargando…

The optical alignment system for luminosity detector at ILC

The possibility to use semi-transparent silicon detectors to measure the displacement detector luminosity LumiCal, planned for the future linear accelerator ILC / CLIC, was studied using an optical laser system based on these detectors. Preliminary results of measurements were achieved using the pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Banas, E, Daniluk, W, Kielar, E, Kotula, J, Krupa, B, Moszczynski, A, Oliwa, K, Pawlik, B, Wierba, W, Zawiejski, L
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:http://cds.cern.ch/record/1992846
_version_ 1780945815226810368
author Banas, E
Daniluk, W
Kielar, E
Kotula, J
Krupa, B
Moszczynski, A
Oliwa, K
Pawlik, B
Wierba, W
Zawiejski, L
author_facet Banas, E
Daniluk, W
Kielar, E
Kotula, J
Krupa, B
Moszczynski, A
Oliwa, K
Pawlik, B
Wierba, W
Zawiejski, L
author_sort Banas, E
collection CERN
description The possibility to use semi-transparent silicon detectors to measure the displacement detector luminosity LumiCal, planned for the future linear accelerator ILC / CLIC, was studied using an optical laser system based on these detectors. Preliminary results of measurements were achieved using the prototype of this system provided in the displacement measurement values of the X and Y directions with an accuracy of a few microns.
format info:eu-repo/semantics/article
id cern-1992846
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-19928462019-09-30T06:29:59Z http://cds.cern.ch/record/1992846 eng Banas, E Daniluk, W Kielar, E Kotula, J Krupa, B Moszczynski, A Oliwa, K Pawlik, B Wierba, W Zawiejski, L The optical alignment system for luminosity detector at ILC Detectors and Experimental Techniques 9: Advanced infrastructures for detector R&D 9.5:Highly Granular Calorimetry The possibility to use semi-transparent silicon detectors to measure the displacement detector luminosity LumiCal, planned for the future linear accelerator ILC / CLIC, was studied using an optical laser system based on these detectors. Preliminary results of measurements were achieved using the prototype of this system provided in the displacement measurement values of the X and Y directions with an accuracy of a few microns. info:eu-repo/grantAgreement/EC/FP7/262025 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1992846 2015
spellingShingle Detectors and Experimental Techniques
9: Advanced infrastructures for detector R&D
9.5:Highly Granular Calorimetry
Banas, E
Daniluk, W
Kielar, E
Kotula, J
Krupa, B
Moszczynski, A
Oliwa, K
Pawlik, B
Wierba, W
Zawiejski, L
The optical alignment system for luminosity detector at ILC
title The optical alignment system for luminosity detector at ILC
title_full The optical alignment system for luminosity detector at ILC
title_fullStr The optical alignment system for luminosity detector at ILC
title_full_unstemmed The optical alignment system for luminosity detector at ILC
title_short The optical alignment system for luminosity detector at ILC
title_sort optical alignment system for luminosity detector at ilc
topic Detectors and Experimental Techniques
9: Advanced infrastructures for detector R&D
9.5:Highly Granular Calorimetry
url http://cds.cern.ch/record/1992846
http://cds.cern.ch/record/1992846
work_keys_str_mv AT banase theopticalalignmentsystemforluminositydetectoratilc
AT danilukw theopticalalignmentsystemforluminositydetectoratilc
AT kielare theopticalalignmentsystemforluminositydetectoratilc
AT kotulaj theopticalalignmentsystemforluminositydetectoratilc
AT krupab theopticalalignmentsystemforluminositydetectoratilc
AT moszczynskia theopticalalignmentsystemforluminositydetectoratilc
AT oliwak theopticalalignmentsystemforluminositydetectoratilc
AT pawlikb theopticalalignmentsystemforluminositydetectoratilc
AT wierbaw theopticalalignmentsystemforluminositydetectoratilc
AT zawiejskil theopticalalignmentsystemforluminositydetectoratilc
AT banase opticalalignmentsystemforluminositydetectoratilc
AT danilukw opticalalignmentsystemforluminositydetectoratilc
AT kielare opticalalignmentsystemforluminositydetectoratilc
AT kotulaj opticalalignmentsystemforluminositydetectoratilc
AT krupab opticalalignmentsystemforluminositydetectoratilc
AT moszczynskia opticalalignmentsystemforluminositydetectoratilc
AT oliwak opticalalignmentsystemforluminositydetectoratilc
AT pawlikb opticalalignmentsystemforluminositydetectoratilc
AT wierbaw opticalalignmentsystemforluminositydetectoratilc
AT zawiejskil opticalalignmentsystemforluminositydetectoratilc