Cargando…
Upgrade to the Birmingham Irradiation Facility
The Birmingham Irradiation Facility was developed in 2013 at the University of Birmingham using the Medical Physics MC40 cyclotron. It can achieve High Luminosity LHC (HL-LHC) fluences of 10^15 (1 MeV neutron equivalent (neq)) cm^-2 in 80 s with proton beam currents of 1 μA and so can evaluate effec...
Autores principales: | , , , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
Nucl. Instrum. Methods Phys. Res., A
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2015.02.005 http://cds.cern.ch/record/1999149 |
_version_ | 1780945909395226624 |
---|---|
author | Dervan, P French, R Hodgson, P Marin- Reyes Parker, K Wilson, J Baca, M |
author_facet | Dervan, P French, R Hodgson, P Marin- Reyes Parker, K Wilson, J Baca, M |
author_sort | Dervan, P |
collection | CERN |
description | The Birmingham Irradiation Facility was developed in 2013 at the University of Birmingham using the Medical Physics MC40 cyclotron. It can achieve High Luminosity LHC (HL-LHC) fluences of 10^15 (1 MeV neutron equivalent (neq)) cm^-2 in 80 s with proton beam currents of 1 μA and so can evaluate effectively the performance and durability of detector technologies and new components to be used for the HL-LHC. Irradiations of silicon sensors and passive materials can be carried out in a temperature controlled cold box which moves continuously through the homogenous beamspot. This movement is provided by a pre-configured XY-axis Cartesian robot scanning system. In 2014 the cooling system and cold box were upgraded from a recirculating glycol chiller system to a liquid nitrogen evaporative system. The new cooling system achieves a stable temperature of 50 1C in 30 min and aims to maintain sub-0 1C temperatures on the sensors during irradiations. This paper reviews the design, development, commissioning and performance of the new cooling system. |
format | info:eu-repo/semantics/article |
id | cern-1999149 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
publisher | Nucl. Instrum. Methods Phys. Res., A |
record_format | invenio |
spelling | cern-19991492022-08-10T12:53:14Z doi:10.1016/j.nima.2015.02.005 http://cds.cern.ch/record/1999149 eng Dervan, P French, R Hodgson, P Marin- Reyes Parker, K Wilson, J Baca, M Upgrade to the Birmingham Irradiation Facility Detectors and Experimental Techniques 8: Improvement and equipment of irradiation and test beam lines 8.3: Upgrade of PS proton and mixed-field irradiation facilities at CERN The Birmingham Irradiation Facility was developed in 2013 at the University of Birmingham using the Medical Physics MC40 cyclotron. It can achieve High Luminosity LHC (HL-LHC) fluences of 10^15 (1 MeV neutron equivalent (neq)) cm^-2 in 80 s with proton beam currents of 1 μA and so can evaluate effectively the performance and durability of detector technologies and new components to be used for the HL-LHC. Irradiations of silicon sensors and passive materials can be carried out in a temperature controlled cold box which moves continuously through the homogenous beamspot. This movement is provided by a pre-configured XY-axis Cartesian robot scanning system. In 2014 the cooling system and cold box were upgraded from a recirculating glycol chiller system to a liquid nitrogen evaporative system. The new cooling system achieves a stable temperature of 50 1C in 30 min and aims to maintain sub-0 1C temperatures on the sensors during irradiations. This paper reviews the design, development, commissioning and performance of the new cooling system. info:eu-repo/grantAgreement/EC/FP7/262025 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1999149 Nucl. Instrum. Methods Phys. Res., A Nucl. Instrum. Methods Phys. Res., A, (2015) pp. 80-84 2015 |
spellingShingle | Detectors and Experimental Techniques 8: Improvement and equipment of irradiation and test beam lines 8.3: Upgrade of PS proton and mixed-field irradiation facilities at CERN Dervan, P French, R Hodgson, P Marin- Reyes Parker, K Wilson, J Baca, M Upgrade to the Birmingham Irradiation Facility |
title | Upgrade to the Birmingham Irradiation Facility |
title_full | Upgrade to the Birmingham Irradiation Facility |
title_fullStr | Upgrade to the Birmingham Irradiation Facility |
title_full_unstemmed | Upgrade to the Birmingham Irradiation Facility |
title_short | Upgrade to the Birmingham Irradiation Facility |
title_sort | upgrade to the birmingham irradiation facility |
topic | Detectors and Experimental Techniques 8: Improvement and equipment of irradiation and test beam lines 8.3: Upgrade of PS proton and mixed-field irradiation facilities at CERN |
url | https://dx.doi.org/10.1016/j.nima.2015.02.005 http://cds.cern.ch/record/1999149 http://cds.cern.ch/record/1999149 |
work_keys_str_mv | AT dervanp upgradetothebirminghamirradiationfacility AT frenchr upgradetothebirminghamirradiationfacility AT hodgsonp upgradetothebirminghamirradiationfacility AT marinreyes upgradetothebirminghamirradiationfacility AT parkerk upgradetothebirminghamirradiationfacility AT wilsonj upgradetothebirminghamirradiationfacility AT bacam upgradetothebirminghamirradiationfacility |