Cargando…

Trap-assisted decay spectroscopy with ISOLTRAP

Penning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectro...

Descripción completa

Detalles Bibliográficos
Autores principales: Kowalska, M, Naimi, S., Agramunt, J., Algora, A., Beck, D., Blank, B., Blaum, K., Böhm, Ch., Borgmann, Ch., Breitenfeldt, M., Fraile, L.M., George, S., Herfurth, F., Herlert, A., Kreim, S., Lunney, D., Minaya-Ramirez, E., Neidherr, D., Rosenbusch, M., Rubio, B., Schweikhard, L., Stanja, J., Zuber, K.
Publicado: 2015
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2012.04.059
http://cds.cern.ch/record/2007792
_version_ 1780946373826314240
author Kowalska, M
Naimi, S.
Agramunt, J.
Algora, A.
Beck, D.
Blank, B.
Blaum, K.
Böhm, Ch.
Borgmann, Ch.
Breitenfeldt, M.
Fraile, L.M.
George, S.
Herfurth, F.
Herlert, A.
Kreim, S.
Lunney, D.
Minaya-Ramirez, E.
Neidherr, D.
Rosenbusch, M.
Rubio, B.
Schweikhard, L.
Stanja, J.
Zuber, K.
author_facet Kowalska, M
Naimi, S.
Agramunt, J.
Algora, A.
Beck, D.
Blank, B.
Blaum, K.
Böhm, Ch.
Borgmann, Ch.
Breitenfeldt, M.
Fraile, L.M.
George, S.
Herfurth, F.
Herlert, A.
Kreim, S.
Lunney, D.
Minaya-Ramirez, E.
Neidherr, D.
Rosenbusch, M.
Rubio, B.
Schweikhard, L.
Stanja, J.
Zuber, K.
author_sort Kowalska, M
collection CERN
description Penning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectroscopy has been coupled to the ISOLTRAP mass spectrometer at ISOLDE/CERN. The results from studies with stable and radioactive ions show that the setup can be used to perform decay studies on purified short-lived nuclides and to assist mass measurements.
id cern-2007792
institution Organización Europea para la Investigación Nuclear
publishDate 2015
record_format invenio
spelling cern-20077922019-09-30T06:29:59Zdoi:10.1016/j.nima.2012.04.059http://cds.cern.ch/record/2007792Kowalska, MNaimi, S.Agramunt, J.Algora, A.Beck, D.Blank, B.Blaum, K.Böhm, Ch.Borgmann, Ch.Breitenfeldt, M.Fraile, L.M.George, S.Herfurth, F.Herlert, A.Kreim, S.Lunney, D.Minaya-Ramirez, E.Neidherr, D.Rosenbusch, M.Rubio, B.Schweikhard, L.Stanja, J.Zuber, K.Trap-assisted decay spectroscopy with ISOLTRAPPenning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectroscopy has been coupled to the ISOLTRAP mass spectrometer at ISOLDE/CERN. The results from studies with stable and radioactive ions show that the setup can be used to perform decay studies on purified short-lived nuclides and to assist mass measurements.oai:cds.cern.ch:20077922015-04-09T12:39:11Z
spellingShingle Kowalska, M
Naimi, S.
Agramunt, J.
Algora, A.
Beck, D.
Blank, B.
Blaum, K.
Böhm, Ch.
Borgmann, Ch.
Breitenfeldt, M.
Fraile, L.M.
George, S.
Herfurth, F.
Herlert, A.
Kreim, S.
Lunney, D.
Minaya-Ramirez, E.
Neidherr, D.
Rosenbusch, M.
Rubio, B.
Schweikhard, L.
Stanja, J.
Zuber, K.
Trap-assisted decay spectroscopy with ISOLTRAP
title Trap-assisted decay spectroscopy with ISOLTRAP
title_full Trap-assisted decay spectroscopy with ISOLTRAP
title_fullStr Trap-assisted decay spectroscopy with ISOLTRAP
title_full_unstemmed Trap-assisted decay spectroscopy with ISOLTRAP
title_short Trap-assisted decay spectroscopy with ISOLTRAP
title_sort trap-assisted decay spectroscopy with isoltrap
url https://dx.doi.org/10.1016/j.nima.2012.04.059
http://cds.cern.ch/record/2007792
work_keys_str_mv AT kowalskam trapassisteddecayspectroscopywithisoltrap
AT naimis trapassisteddecayspectroscopywithisoltrap
AT agramuntj trapassisteddecayspectroscopywithisoltrap
AT algoraa trapassisteddecayspectroscopywithisoltrap
AT beckd trapassisteddecayspectroscopywithisoltrap
AT blankb trapassisteddecayspectroscopywithisoltrap
AT blaumk trapassisteddecayspectroscopywithisoltrap
AT bohmch trapassisteddecayspectroscopywithisoltrap
AT borgmannch trapassisteddecayspectroscopywithisoltrap
AT breitenfeldtm trapassisteddecayspectroscopywithisoltrap
AT frailelm trapassisteddecayspectroscopywithisoltrap
AT georges trapassisteddecayspectroscopywithisoltrap
AT herfurthf trapassisteddecayspectroscopywithisoltrap
AT herlerta trapassisteddecayspectroscopywithisoltrap
AT kreims trapassisteddecayspectroscopywithisoltrap
AT lunneyd trapassisteddecayspectroscopywithisoltrap
AT minayaramireze trapassisteddecayspectroscopywithisoltrap
AT neidherrd trapassisteddecayspectroscopywithisoltrap
AT rosenbuschm trapassisteddecayspectroscopywithisoltrap
AT rubiob trapassisteddecayspectroscopywithisoltrap
AT schweikhardl trapassisteddecayspectroscopywithisoltrap
AT stanjaj trapassisteddecayspectroscopywithisoltrap
AT zuberk trapassisteddecayspectroscopywithisoltrap