Cargando…
Trap-assisted decay spectroscopy with ISOLTRAP
Penning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectro...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Publicado: |
2015
|
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2012.04.059 http://cds.cern.ch/record/2007792 |
_version_ | 1780946373826314240 |
---|---|
author | Kowalska, M Naimi, S. Agramunt, J. Algora, A. Beck, D. Blank, B. Blaum, K. Böhm, Ch. Borgmann, Ch. Breitenfeldt, M. Fraile, L.M. George, S. Herfurth, F. Herlert, A. Kreim, S. Lunney, D. Minaya-Ramirez, E. Neidherr, D. Rosenbusch, M. Rubio, B. Schweikhard, L. Stanja, J. Zuber, K. |
author_facet | Kowalska, M Naimi, S. Agramunt, J. Algora, A. Beck, D. Blank, B. Blaum, K. Böhm, Ch. Borgmann, Ch. Breitenfeldt, M. Fraile, L.M. George, S. Herfurth, F. Herlert, A. Kreim, S. Lunney, D. Minaya-Ramirez, E. Neidherr, D. Rosenbusch, M. Rubio, B. Schweikhard, L. Stanja, J. Zuber, K. |
author_sort | Kowalska, M |
collection | CERN |
description | Penning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectroscopy has been coupled to the ISOLTRAP mass spectrometer at ISOLDE/CERN. The results from studies with stable and radioactive ions show that the setup can be used to perform decay studies on purified short-lived nuclides and to assist mass measurements. |
id | cern-2007792 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2015 |
record_format | invenio |
spelling | cern-20077922019-09-30T06:29:59Zdoi:10.1016/j.nima.2012.04.059http://cds.cern.ch/record/2007792Kowalska, MNaimi, S.Agramunt, J.Algora, A.Beck, D.Blank, B.Blaum, K.Böhm, Ch.Borgmann, Ch.Breitenfeldt, M.Fraile, L.M.George, S.Herfurth, F.Herlert, A.Kreim, S.Lunney, D.Minaya-Ramirez, E.Neidherr, D.Rosenbusch, M.Rubio, B.Schweikhard, L.Stanja, J.Zuber, K.Trap-assisted decay spectroscopy with ISOLTRAPPenning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectroscopy has been coupled to the ISOLTRAP mass spectrometer at ISOLDE/CERN. The results from studies with stable and radioactive ions show that the setup can be used to perform decay studies on purified short-lived nuclides and to assist mass measurements.oai:cds.cern.ch:20077922015-04-09T12:39:11Z |
spellingShingle | Kowalska, M Naimi, S. Agramunt, J. Algora, A. Beck, D. Blank, B. Blaum, K. Böhm, Ch. Borgmann, Ch. Breitenfeldt, M. Fraile, L.M. George, S. Herfurth, F. Herlert, A. Kreim, S. Lunney, D. Minaya-Ramirez, E. Neidherr, D. Rosenbusch, M. Rubio, B. Schweikhard, L. Stanja, J. Zuber, K. Trap-assisted decay spectroscopy with ISOLTRAP |
title | Trap-assisted decay spectroscopy with ISOLTRAP |
title_full | Trap-assisted decay spectroscopy with ISOLTRAP |
title_fullStr | Trap-assisted decay spectroscopy with ISOLTRAP |
title_full_unstemmed | Trap-assisted decay spectroscopy with ISOLTRAP |
title_short | Trap-assisted decay spectroscopy with ISOLTRAP |
title_sort | trap-assisted decay spectroscopy with isoltrap |
url | https://dx.doi.org/10.1016/j.nima.2012.04.059 http://cds.cern.ch/record/2007792 |
work_keys_str_mv | AT kowalskam trapassisteddecayspectroscopywithisoltrap AT naimis trapassisteddecayspectroscopywithisoltrap AT agramuntj trapassisteddecayspectroscopywithisoltrap AT algoraa trapassisteddecayspectroscopywithisoltrap AT beckd trapassisteddecayspectroscopywithisoltrap AT blankb trapassisteddecayspectroscopywithisoltrap AT blaumk trapassisteddecayspectroscopywithisoltrap AT bohmch trapassisteddecayspectroscopywithisoltrap AT borgmannch trapassisteddecayspectroscopywithisoltrap AT breitenfeldtm trapassisteddecayspectroscopywithisoltrap AT frailelm trapassisteddecayspectroscopywithisoltrap AT georges trapassisteddecayspectroscopywithisoltrap AT herfurthf trapassisteddecayspectroscopywithisoltrap AT herlerta trapassisteddecayspectroscopywithisoltrap AT kreims trapassisteddecayspectroscopywithisoltrap AT lunneyd trapassisteddecayspectroscopywithisoltrap AT minayaramireze trapassisteddecayspectroscopywithisoltrap AT neidherrd trapassisteddecayspectroscopywithisoltrap AT rosenbuschm trapassisteddecayspectroscopywithisoltrap AT rubiob trapassisteddecayspectroscopywithisoltrap AT schweikhardl trapassisteddecayspectroscopywithisoltrap AT stanjaj trapassisteddecayspectroscopywithisoltrap AT zuberk trapassisteddecayspectroscopywithisoltrap |