Real-time alignment and calibration of the LHCb Detector in Run II

Stable, precise spatial alignment and PID calibration are necessary to achieve optimal detector performance. During Run2, LHCb will have a new real-time detector alignment and calibration to allow equivalent performance in the online and offline reconstruction to be reached. This offers the opportun...

Descripción completa

Detalles Bibliográficos
Autores principales: Dujany, Giulio, Storaci, Barbara
Lenguaje:eng
Publicado: 2015
Acceso en línea:http://cds.cern.ch/record/2017836
_version_ 1780946745191038976
author Dujany, Giulio
Storaci, Barbara
author_facet Dujany, Giulio
Storaci, Barbara
author_sort Dujany, Giulio
collection CERN
description Stable, precise spatial alignment and PID calibration are necessary to achieve optimal detector performance. During Run2, LHCb will have a new real-time detector alignment and calibration to allow equivalent performance in the online and offline reconstruction to be reached. This offers the opportunity to optimise the event selection by applying stronger constraints, and to use hadronic particle identification at the trigger level. The computing time constraints are met through the use of a new dedicated framework using the multi-core farm infrastructure for the trigger. The motivation for a real-time alignment and calibration of the LHCb detector is discussed from the operative and physics performance point of view. Specific challenges of this configuration are discussed, as well as the designed framework and its performance.
id cern-2017836
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-20178362019-09-30T06:29:59Zhttp://cds.cern.ch/record/2017836engDujany, GiulioStoraci, BarbaraReal-time alignment and calibration of the LHCb Detector in Run IIStable, precise spatial alignment and PID calibration are necessary to achieve optimal detector performance. During Run2, LHCb will have a new real-time detector alignment and calibration to allow equivalent performance in the online and offline reconstruction to be reached. This offers the opportunity to optimise the event selection by applying stronger constraints, and to use hadronic particle identification at the trigger level. The computing time constraints are met through the use of a new dedicated framework using the multi-core farm infrastructure for the trigger. The motivation for a real-time alignment and calibration of the LHCb detector is discussed from the operative and physics performance point of view. Specific challenges of this configuration are discussed, as well as the designed framework and its performance.Poster-2015-488oai:cds.cern.ch:20178362015-04-13
spellingShingle Dujany, Giulio
Storaci, Barbara
Real-time alignment and calibration of the LHCb Detector in Run II
title Real-time alignment and calibration of the LHCb Detector in Run II
title_full Real-time alignment and calibration of the LHCb Detector in Run II
title_fullStr Real-time alignment and calibration of the LHCb Detector in Run II
title_full_unstemmed Real-time alignment and calibration of the LHCb Detector in Run II
title_short Real-time alignment and calibration of the LHCb Detector in Run II
title_sort real-time alignment and calibration of the lhcb detector in run ii
url http://cds.cern.ch/record/2017836
work_keys_str_mv AT dujanygiulio realtimealignmentandcalibrationofthelhcbdetectorinrunii
AT storacibarbara realtimealignmentandcalibrationofthelhcbdetectorinrunii