Cargando…
Characterizations of GEM detector prototype
At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are performed. The method and test results are presented.
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2015.11.087 http://cds.cern.ch/record/2020505 |
_version_ | 1780946848816562176 |
---|---|
author | Patra, Rajendra Nath Nanda, Amit Rudra, Sharmili Bhattacharya, P. Sahoo, Sumanya Sekhar Biswas, S. Mohanty, B. Nayak, T.K. Sahu, P.K. Sahu, S. |
author_facet | Patra, Rajendra Nath Nanda, Amit Rudra, Sharmili Bhattacharya, P. Sahoo, Sumanya Sekhar Biswas, S. Mohanty, B. Nayak, T.K. Sahu, P.K. Sahu, S. |
author_sort | Patra, Rajendra Nath |
collection | CERN |
description | At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are performed. The method and test results are presented. |
id | cern-2020505 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | cern-20205052023-03-14T17:43:30Zdoi:10.1016/j.nima.2015.11.087http://cds.cern.ch/record/2020505engPatra, Rajendra NathNanda, AmitRudra, SharmiliBhattacharya, P.Sahoo, Sumanya SekharBiswas, S.Mohanty, B.Nayak, T.K.Sahu, P.K.Sahu, S.Characterizations of GEM detector prototypeDetectors and Experimental TechniquesAt NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are performed. The method and test results are presented.At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are performed. The method and test results are presented.arXiv:1505.07768oai:cds.cern.ch:20205052015-05-26 |
spellingShingle | Detectors and Experimental Techniques Patra, Rajendra Nath Nanda, Amit Rudra, Sharmili Bhattacharya, P. Sahoo, Sumanya Sekhar Biswas, S. Mohanty, B. Nayak, T.K. Sahu, P.K. Sahu, S. Characterizations of GEM detector prototype |
title | Characterizations of GEM detector prototype |
title_full | Characterizations of GEM detector prototype |
title_fullStr | Characterizations of GEM detector prototype |
title_full_unstemmed | Characterizations of GEM detector prototype |
title_short | Characterizations of GEM detector prototype |
title_sort | characterizations of gem detector prototype |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2015.11.087 http://cds.cern.ch/record/2020505 |
work_keys_str_mv | AT patrarajendranath characterizationsofgemdetectorprototype AT nandaamit characterizationsofgemdetectorprototype AT rudrasharmili characterizationsofgemdetectorprototype AT bhattacharyap characterizationsofgemdetectorprototype AT sahoosumanyasekhar characterizationsofgemdetectorprototype AT biswass characterizationsofgemdetectorprototype AT mohantyb characterizationsofgemdetectorprototype AT nayaktk characterizationsofgemdetectorprototype AT sahupk characterizationsofgemdetectorprototype AT sahus characterizationsofgemdetectorprototype |