Cargando…

Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors

Resistive strip Micromegas detectors are discharge tolerant. They have been tested extensively as small detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100 kHz/cm$^2$ and above. Tracking resolution well below 100 $\mu$m has been observed for 100 GeV muons and pions....

Descripción completa

Detalles Bibliográficos
Autor principal: Losel, Philipp Jonathan
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2015.11.063
http://cds.cern.ch/record/2026916
_version_ 1780947283125207040
author Losel, Philipp Jonathan
author_facet Losel, Philipp Jonathan
author_sort Losel, Philipp Jonathan
collection CERN
description Resistive strip Micromegas detectors are discharge tolerant. They have been tested extensively as small detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100 kHz/cm$^2$ and above. Tracking resolution well below 100 $\mu$m has been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3 m$^2$ in size. To investigate possible differences between small and large detectors, a 1 m$^2$ detector with 2048 resistive strips at a pitch of 450 $\mu$m was studied in the LMU Cosmic Ray Measurement Facility (CRMF) using two 4 $\times$ 2.2 m$^2$ large Monitored Drift Tube (MDT) chambers for cosmic muon reference tracking. A segmentation of the resistive strip anode plane in 57.6 mm x 93 mm large areas has been realized by the readout of 128 strips with one APV25 chip each and by eleven 93 mm broad trigger scintillators placed along the readout strips. This allows for mapping of homogeneity in pulse height and efficiency, determination of signal propagation along the 1m long anode strips and calibration of the position of the anode strips.
id cern-2026916
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-20269162019-09-30T06:29:59Zdoi:10.1016/j.nima.2015.11.063http://cds.cern.ch/record/2026916engLosel, Philipp JonathanCharacterization and Calibration of Large Area Resistive Strip Micromegas DetectorsParticle Physics - ExperimentResistive strip Micromegas detectors are discharge tolerant. They have been tested extensively as small detectors of about 10 x 10 cm$^2$ in size and they work reliably at high rates of 100 kHz/cm$^2$ and above. Tracking resolution well below 100 $\mu$m has been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3 m$^2$ in size. To investigate possible differences between small and large detectors, a 1 m$^2$ detector with 2048 resistive strips at a pitch of 450 $\mu$m was studied in the LMU Cosmic Ray Measurement Facility (CRMF) using two 4 $\times$ 2.2 m$^2$ large Monitored Drift Tube (MDT) chambers for cosmic muon reference tracking. A segmentation of the resistive strip anode plane in 57.6 mm x 93 mm large areas has been realized by the readout of 128 strips with one APV25 chip each and by eleven 93 mm broad trigger scintillators placed along the readout strips. This allows for mapping of homogeneity in pulse height and efficiency, determination of signal propagation along the 1m long anode strips and calibration of the position of the anode strips.ATL-MUON-PROC-2015-003oai:cds.cern.ch:20269162015-06-23
spellingShingle Particle Physics - Experiment
Losel, Philipp Jonathan
Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors
title Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors
title_full Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors
title_fullStr Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors
title_full_unstemmed Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors
title_short Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors
title_sort characterization and calibration of large area resistive strip micromegas detectors
topic Particle Physics - Experiment
url https://dx.doi.org/10.1016/j.nima.2015.11.063
http://cds.cern.ch/record/2026916
work_keys_str_mv AT loselphilippjonathan characterizationandcalibrationoflargearearesistivestripmicromegasdetectors