Quadrupole Transfer Function for Emittance Measurement

Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution li...

Descripción completa

Detalles Bibliográficos
Autores principales: Cameron, Peter, Gasior, Marek, Jansson, Andreas, Tan, Cheng-Yang
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:http://cds.cern.ch/record/2032806
_version_ 1780947548266037248
author Cameron, Peter
Gasior, Marek
Jansson, Andreas
Tan, Cheng-Yang
author_facet Cameron, Peter
Gasior, Marek
Jansson, Andreas
Tan, Cheng-Yang
author_sort Cameron, Peter
collection CERN
description Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC.
id cern-2032806
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-20328062022-08-17T13:36:01Zhttp://cds.cern.ch/record/2032806engCameron, PeterGasior, MarekJansson, AndreasTan, Cheng-YangQuadrupole Transfer Function for Emittance MeasurementAccelerators and Storage RingsHistorically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC.oai:cds.cern.ch:20328062008
spellingShingle Accelerators and Storage Rings
Cameron, Peter
Gasior, Marek
Jansson, Andreas
Tan, Cheng-Yang
Quadrupole Transfer Function for Emittance Measurement
title Quadrupole Transfer Function for Emittance Measurement
title_full Quadrupole Transfer Function for Emittance Measurement
title_fullStr Quadrupole Transfer Function for Emittance Measurement
title_full_unstemmed Quadrupole Transfer Function for Emittance Measurement
title_short Quadrupole Transfer Function for Emittance Measurement
title_sort quadrupole transfer function for emittance measurement
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2032806
work_keys_str_mv AT cameronpeter quadrupoletransferfunctionforemittancemeasurement
AT gasiormarek quadrupoletransferfunctionforemittancemeasurement
AT janssonandreas quadrupoletransferfunctionforemittancemeasurement
AT tanchengyang quadrupoletransferfunctionforemittancemeasurement