Cargando…
Quadrupole Transfer Function for Emittance Measurement
Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution li...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2032806 |
_version_ | 1780947548266037248 |
---|---|
author | Cameron, Peter Gasior, Marek Jansson, Andreas Tan, Cheng-Yang |
author_facet | Cameron, Peter Gasior, Marek Jansson, Andreas Tan, Cheng-Yang |
author_sort | Cameron, Peter |
collection | CERN |
description | Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC. |
id | cern-2032806 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-20328062022-08-17T13:36:01Zhttp://cds.cern.ch/record/2032806engCameron, PeterGasior, MarekJansson, AndreasTan, Cheng-YangQuadrupole Transfer Function for Emittance MeasurementAccelerators and Storage RingsHistorically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC.oai:cds.cern.ch:20328062008 |
spellingShingle | Accelerators and Storage Rings Cameron, Peter Gasior, Marek Jansson, Andreas Tan, Cheng-Yang Quadrupole Transfer Function for Emittance Measurement |
title | Quadrupole Transfer Function for Emittance Measurement |
title_full | Quadrupole Transfer Function for Emittance Measurement |
title_fullStr | Quadrupole Transfer Function for Emittance Measurement |
title_full_unstemmed | Quadrupole Transfer Function for Emittance Measurement |
title_short | Quadrupole Transfer Function for Emittance Measurement |
title_sort | quadrupole transfer function for emittance measurement |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/2032806 |
work_keys_str_mv | AT cameronpeter quadrupoletransferfunctionforemittancemeasurement AT gasiormarek quadrupoletransferfunctionforemittancemeasurement AT janssonandreas quadrupoletransferfunctionforemittancemeasurement AT tanchengyang quadrupoletransferfunctionforemittancemeasurement |