Cargando…
Calibrating the sensing-coil radius by feed-down from a harmonic reference
A method for calibrating the radius of rotating, harmonic sensing coils is proposed that allows relaxing constraints on alignment and field errors of the reference quadrupole magnet. Radius calibration considering roll angle misalignment between the measurement bench, the magnet, and the motor-drive...
Autores principales: | , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2037059 |
_version_ | 1780947658209230848 |
---|---|
author | Arpaia, Pasquale Buzio, Marco Koster, Oliver Russenschuck, Stephan Severino, Giordana |
author_facet | Arpaia, Pasquale Buzio, Marco Koster, Oliver Russenschuck, Stephan Severino, Giordana |
author_sort | Arpaia, Pasquale |
collection | CERN |
description | A method for calibrating the radius of rotating, harmonic sensing coils is proposed that allows relaxing constraints on alignment and field errors of the reference quadrupole magnet. Radius calibration considering roll angle misalignment between the measurement bench, the magnet, and the motor-drive unit is studied first. We then study the calibration error when
a harmonic field error of higher order is present in the calibration magnet. This also yields a calibration whena sextupole magnet is used, for example, when an insitu calibration is required. The proposed calibration method has been validated by simulations with the |
format | info:eu-repo/semantics/article |
id | cern-2037059 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | cern-20370592019-09-30T06:29:59Z http://cds.cern.ch/record/2037059 eng Arpaia, Pasquale Buzio, Marco Koster, Oliver Russenschuck, Stephan Severino, Giordana Calibrating the sensing-coil radius by feed-down from a harmonic reference Mathematical Physics and Mathematics A method for calibrating the radius of rotating, harmonic sensing coils is proposed that allows relaxing constraints on alignment and field errors of the reference quadrupole magnet. Radius calibration considering roll angle misalignment between the measurement bench, the magnet, and the motor-drive unit is studied first. We then study the calibration error when a harmonic field error of higher order is present in the calibration magnet. This also yields a calibration whena sextupole magnet is used, for example, when an insitu calibration is required. The proposed calibration method has been validated by simulations with the info:eu-repo/grantAgreement/EC/FP7/606839 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2037059 2015 |
spellingShingle | Mathematical Physics and Mathematics Arpaia, Pasquale Buzio, Marco Koster, Oliver Russenschuck, Stephan Severino, Giordana Calibrating the sensing-coil radius by feed-down from a harmonic reference |
title | Calibrating the sensing-coil radius by feed-down from a harmonic reference |
title_full | Calibrating the sensing-coil radius by feed-down from a harmonic reference |
title_fullStr | Calibrating the sensing-coil radius by feed-down from a harmonic reference |
title_full_unstemmed | Calibrating the sensing-coil radius by feed-down from a harmonic reference |
title_short | Calibrating the sensing-coil radius by feed-down from a harmonic reference |
title_sort | calibrating the sensing-coil radius by feed-down from a harmonic reference |
topic | Mathematical Physics and Mathematics |
url | http://cds.cern.ch/record/2037059 http://cds.cern.ch/record/2037059 |
work_keys_str_mv | AT arpaiapasquale calibratingthesensingcoilradiusbyfeeddownfromaharmonicreference AT buziomarco calibratingthesensingcoilradiusbyfeeddownfromaharmonicreference AT kosteroliver calibratingthesensingcoilradiusbyfeeddownfromaharmonicreference AT russenschuckstephan calibratingthesensingcoilradiusbyfeeddownfromaharmonicreference AT severinogiordana calibratingthesensingcoilradiusbyfeeddownfromaharmonicreference |