Cargando…
Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements
The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-m regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Na...
Autores principales: | , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
Meas. Sci. Technol.
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/0957-0233/26/9/094005 http://cds.cern.ch/record/2039354 |
_version_ | 1780947727214968832 |
---|---|
author | Silvia Zorzetti, Silvia Fanucci, Luca Galindo Muño, Natalia Wendt, Manfred |
author_facet | Silvia Zorzetti, Silvia Fanucci, Luca Galindo Muño, Natalia Wendt, Manfred |
author_sort | Silvia Zorzetti, Silvia |
collection | CERN |
description | The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-m regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) PhD training action a study with the objective of pre-aligning the electrical centre of a 15 GHz cavity beam position monitor (BPM) to the magnetic centre of the main beam quadrupole is initiated. Of particular importance is the design of a specific test bench to study the stretched-wire setup for the CLIC Test Facility (CTF3) BPM, focusing on the aspects of microwave signal excitation, transmission and impedance-matching, as well as the mechanical setup and reproducibility of the measurement method. |
format | info:eu-repo/semantics/article |
id | cern-2039354 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
publisher | Meas. Sci. Technol. |
record_format | invenio |
spelling | cern-20393542019-09-30T06:29:59Z doi:10.1088/0957-0233/26/9/094005 http://cds.cern.ch/record/2039354 eng Silvia Zorzetti, Silvia Fanucci, Luca Galindo Muño, Natalia Wendt, Manfred Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements Engineering The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-m regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) PhD training action a study with the objective of pre-aligning the electrical centre of a 15 GHz cavity beam position monitor (BPM) to the magnetic centre of the main beam quadrupole is initiated. Of particular importance is the design of a specific test bench to study the stretched-wire setup for the CLIC Test Facility (CTF3) BPM, focusing on the aspects of microwave signal excitation, transmission and impedance-matching, as well as the mechanical setup and reproducibility of the measurement method. info:eu-repo/grantAgreement/EC/FP7/606839 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2039354 Meas. Sci. Technol. Meas. Sci. Technol., (2015) pp. 094005 2015 |
spellingShingle | Engineering Silvia Zorzetti, Silvia Fanucci, Luca Galindo Muño, Natalia Wendt, Manfred Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements |
title | Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements |
title_full | Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements |
title_fullStr | Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements |
title_full_unstemmed | Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements |
title_short | Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements |
title_sort | design of the 15 ghz bpm test bench for the clic test facility to perform precise stretchedwire rf measurements |
topic | Engineering |
url | https://dx.doi.org/10.1088/0957-0233/26/9/094005 http://cds.cern.ch/record/2039354 http://cds.cern.ch/record/2039354 |
work_keys_str_mv | AT silviazorzettisilvia designofthe15ghzbpmtestbenchfortheclictestfacilitytoperformprecisestretchedwirerfmeasurements AT fanucciluca designofthe15ghzbpmtestbenchfortheclictestfacilitytoperformprecisestretchedwirerfmeasurements AT galindomunonatalia designofthe15ghzbpmtestbenchfortheclictestfacilitytoperformprecisestretchedwirerfmeasurements AT wendtmanfred designofthe15ghzbpmtestbenchfortheclictestfacilitytoperformprecisestretchedwirerfmeasurements |