Cargando…

On the simulation of limit thresholds for ISOLDE decay station neutron detector

The recently comissioned ISOLDE decay station neutron detector (IDSN) efficiency was calibrated with a standard 252Cf neutron source, using lower threshold limits set at 0, 31 keV and 59.5 keV, and upper threhold of 3840 keV. Geant4 simulations were run to compare with the experimental efficiency wh...

Descripción completa

Detalles Bibliográficos
Autor principal: Arce Gamboa, José Rafael
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:http://cds.cern.ch/record/2047067
_version_ 1780947966492672000
author Arce Gamboa, José Rafael
author_facet Arce Gamboa, José Rafael
author_sort Arce Gamboa, José Rafael
collection CERN
description The recently comissioned ISOLDE decay station neutron detector (IDSN) efficiency was calibrated with a standard 252Cf neutron source, using lower threshold limits set at 0, 31 keV and 59.5 keV, and upper threhold of 3840 keV. Geant4 simulations were run to compare with the experimental efficiency where new detector limits were sought to fit the experimental data. Suitable values of limit thresholds were found that properly fit the simulation with experimental lower neutron energies, below 1 MeV, but strongly departs from data above it. It is concluded that the simulation is incomplete at this point, and so a review must be done on the nuclear physics and scintillation light Geant4 packages in order to properly reproduce the detector properties.
id cern-2047067
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-20470672019-09-30T06:29:59Zhttp://cds.cern.ch/record/2047067engArce Gamboa, José RafaelOn the simulation of limit thresholds for ISOLDE decay station neutron detectorNuclear Physics - ExperimentDetectors and Experimental TechniquesThe recently comissioned ISOLDE decay station neutron detector (IDSN) efficiency was calibrated with a standard 252Cf neutron source, using lower threshold limits set at 0, 31 keV and 59.5 keV, and upper threhold of 3840 keV. Geant4 simulations were run to compare with the experimental efficiency where new detector limits were sought to fit the experimental data. Suitable values of limit thresholds were found that properly fit the simulation with experimental lower neutron energies, below 1 MeV, but strongly departs from data above it. It is concluded that the simulation is incomplete at this point, and so a review must be done on the nuclear physics and scintillation light Geant4 packages in order to properly reproduce the detector properties.CERN-STUDENTS-Note-2015-080CERN-STUDENTS-Note-2015-130oai:cds.cern.ch:20470672015-08-26
spellingShingle Nuclear Physics - Experiment
Detectors and Experimental Techniques
Arce Gamboa, José Rafael
On the simulation of limit thresholds for ISOLDE decay station neutron detector
title On the simulation of limit thresholds for ISOLDE decay station neutron detector
title_full On the simulation of limit thresholds for ISOLDE decay station neutron detector
title_fullStr On the simulation of limit thresholds for ISOLDE decay station neutron detector
title_full_unstemmed On the simulation of limit thresholds for ISOLDE decay station neutron detector
title_short On the simulation of limit thresholds for ISOLDE decay station neutron detector
title_sort on the simulation of limit thresholds for isolde decay station neutron detector
topic Nuclear Physics - Experiment
Detectors and Experimental Techniques
url http://cds.cern.ch/record/2047067
work_keys_str_mv AT arcegamboajoserafael onthesimulationoflimitthresholdsforisoldedecaystationneutrondetector