Cargando…

Magnetic field mapping for HIE-ISOLDE cavities

In this report the importance of a magnetic field mapping (B-mapping) around the HIE-ISOLDE superconducting cavities is described. In fact the cavities are not always above the HIE-ISOLDE specification, so it is important to understand the reason of their bad performances and improve them. For doing...

Descripción completa

Detalles Bibliográficos
Autor principal: Bianchi, Antonio
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:http://cds.cern.ch/record/2051930
Descripción
Sumario:In this report the importance of a magnetic field mapping (B-mapping) around the HIE-ISOLDE superconducting cavities is described. In fact the cavities are not always above the HIE-ISOLDE specification, so it is important to understand the reason of their bad performances and improve them. For doing the B-mapping, the supports for three fluxgate sensors are designed and manufactured. The material of the supports is PEEK: a proper thermoplastic for the extreme operation conditions of the cavities. According to simulation of behavior of external magnetic field, an initial configuration of the sensors is proposed for the first measurements, in order to get the extent of Meissner effect around the superconducting cavities.