Lyman Alpha Control

This document gives an overview of how to operate the Lyman Alpha Control application written in LabVIEW along with things to watch out for. Overview of the LabVIEW code itself as well as the physical wiring of and connections from/to the NI PCI-6229 DAQ box is also included. The Lyman Alpha Control...

Descripción completa

Detalles Bibliográficos
Autor principal: Nielsen, Daniel Stefaniak
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:http://cds.cern.ch/record/2054946
_version_ 1780948259075784704
author Nielsen, Daniel Stefaniak
author_facet Nielsen, Daniel Stefaniak
author_sort Nielsen, Daniel Stefaniak
collection CERN
description This document gives an overview of how to operate the Lyman Alpha Control application written in LabVIEW along with things to watch out for. Overview of the LabVIEW code itself as well as the physical wiring of and connections from/to the NI PCI-6229 DAQ box is also included. The Lyman Alpha Control application is the interface between the ALPHA sequencer and the HighFinesse Wavelength Meter as well as the Lyman Alpha laser setup. The application measures the wavelength of the output light from the Lyman Alpha cavity through the Wavelength Meter. The application can use the Wavelength Meter’s PID capabilities to stabilize the Lyman Alpha laser output as well as switch between up to three frequencies.
id cern-2054946
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-20549462019-09-30T06:29:59Zhttp://cds.cern.ch/record/2054946engNielsen, Daniel StefaniakLyman Alpha ControlOther SubjectsThis document gives an overview of how to operate the Lyman Alpha Control application written in LabVIEW along with things to watch out for. Overview of the LabVIEW code itself as well as the physical wiring of and connections from/to the NI PCI-6229 DAQ box is also included. The Lyman Alpha Control application is the interface between the ALPHA sequencer and the HighFinesse Wavelength Meter as well as the Lyman Alpha laser setup. The application measures the wavelength of the output light from the Lyman Alpha cavity through the Wavelength Meter. The application can use the Wavelength Meter’s PID capabilities to stabilize the Lyman Alpha laser output as well as switch between up to three frequencies.CERN-STUDENTS-Note-2015-221oai:cds.cern.ch:20549462015-09-24
spellingShingle Other Subjects
Nielsen, Daniel Stefaniak
Lyman Alpha Control
title Lyman Alpha Control
title_full Lyman Alpha Control
title_fullStr Lyman Alpha Control
title_full_unstemmed Lyman Alpha Control
title_short Lyman Alpha Control
title_sort lyman alpha control
topic Other Subjects
url http://cds.cern.ch/record/2054946
work_keys_str_mv AT nielsendanielstefaniak lymanalphacontrol