Cargando…

Timing performances of diamond detectors with Charge Sensitive Amplifier readout

Research on particle detector based on synthetic diamonds has always been limited by the cost, quality and availability of the sensitive material. Moreover, the read-out electronics requires particular care due to the small number of electron/hole pairs generated by the passage of a minimum ionizin...

Descripción completa

Detalles Bibliográficos
Autores principales: Berretti, M, Bossini, E, Minafra, N
Lenguaje:eng
Publicado: 2015
Acceso en línea:http://cds.cern.ch/record/2055747
_version_ 1780948315924332544
author Berretti, M
Bossini, E
Minafra, N
author_facet Berretti, M
Bossini, E
Minafra, N
author_sort Berretti, M
collection CERN
description Research on particle detector based on synthetic diamonds has always been limited by the cost, quality and availability of the sensitive material. Moreover, the read-out electronics requires particular care due to the small number of electron/hole pairs generated by the passage of a minimum ionizing particle. However, high radiation hardness, low leakage currents and high mobility of the electron/hole pairs make them an attractive solution for the time of flight measurements and the beam monitoring of new high energy physics experiments where the severe radiation environment is a limitation for most of the technologies commonly used in particle detection. In this work we report the results on the timing performance of a 4.5x4.5 mm$^{2}$ scCVD sensor read-out using a charge sensitive amplifier. Both sensors and amplifiers have been purchased from CIVIDEC Instrumentation. The measurement have been performed on minimum ionizing pions in two beam tests at the PSI and CERN-PS facilities with two different detector capacitances. In particular, a time resolution of the order of 200 ps has been obtained.
id cern-2055747
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-20557472019-09-30T06:29:59Zhttp://cds.cern.ch/record/2055747engBerretti, MBossini, EMinafra, NTiming performances of diamond detectors with Charge Sensitive Amplifier readoutResearch on particle detector based on synthetic diamonds has always been limited by the cost, quality and availability of the sensitive material. Moreover, the read-out electronics requires particular care due to the small number of electron/hole pairs generated by the passage of a minimum ionizing particle. However, high radiation hardness, low leakage currents and high mobility of the electron/hole pairs make them an attractive solution for the time of flight measurements and the beam monitoring of new high energy physics experiments where the severe radiation environment is a limitation for most of the technologies commonly used in particle detection. In this work we report the results on the timing performance of a 4.5x4.5 mm$^{2}$ scCVD sensor read-out using a charge sensitive amplifier. Both sensors and amplifiers have been purchased from CIVIDEC Instrumentation. The measurement have been performed on minimum ionizing pions in two beam tests at the PSI and CERN-PS facilities with two different detector capacitances. In particular, a time resolution of the order of 200 ps has been obtained.CERN-TOTEM-NOTE-2015-003oai:cds.cern.ch:20557472015-09-28
spellingShingle Berretti, M
Bossini, E
Minafra, N
Timing performances of diamond detectors with Charge Sensitive Amplifier readout
title Timing performances of diamond detectors with Charge Sensitive Amplifier readout
title_full Timing performances of diamond detectors with Charge Sensitive Amplifier readout
title_fullStr Timing performances of diamond detectors with Charge Sensitive Amplifier readout
title_full_unstemmed Timing performances of diamond detectors with Charge Sensitive Amplifier readout
title_short Timing performances of diamond detectors with Charge Sensitive Amplifier readout
title_sort timing performances of diamond detectors with charge sensitive amplifier readout
url http://cds.cern.ch/record/2055747
work_keys_str_mv AT berrettim timingperformancesofdiamonddetectorswithchargesensitiveamplifierreadout
AT bossinie timingperformancesofdiamonddetectorswithchargesensitiveamplifierreadout
AT minafran timingperformancesofdiamonddetectorswithchargesensitiveamplifierreadout