Cargando…
Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator
The systematic research on superconducting thin films requires dedicated testing equipment. The Quadrupole Resonator (QPR) is a specialized tool to characterize the superconducting RF properties of circular planar samples. A calorimetric measurement of the RF surface losses allows the surface resist...
Autores principales: | , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-SRF2015-TUPB067 http://cds.cern.ch/record/2058161 |
_version_ | 1780948383199920128 |
---|---|
author | Keckert, Sebastian Kleindienst, Raphael Knobloch, Jens Kugeler, Oliver |
author_facet | Keckert, Sebastian Kleindienst, Raphael Knobloch, Jens Kugeler, Oliver |
author_sort | Keckert, Sebastian |
collection | CERN |
description | The systematic research on superconducting thin films requires dedicated testing equipment. The Quadrupole Resonator (QPR) is a specialized tool to characterize the superconducting RF properties of circular planar samples. A calorimetric measurement of the RF surface losses allows the surface resistance to be measured with sub nano-ohm resolution. This measurement can be performed over a wide temperature and magnetic field range, at frequencies of 433, 866 and 1300 MHz. The system at Helmholtz-Zentrum Berlin (HZB) is based on a resonator built at CERN and has been optimized to lower peak electric fields and an improved resolution.
In this paper the design of an alternative calorimetry chamber is presented, providing flat samples for coating which are easy changeable. All parts are connected by screwing connections and no electron beam welding is required. Furthermore this design enables exchangeability of samples between the resonators at HZB and CERN.
First measurements with the new design show ambiguous results, partly explainable by RF losses at the indium gasket. |
format | info:eu-repo/semantics/article |
id | cern-2058161 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | cern-20581612019-09-30T06:29:59Z doi:10.18429/JACoW-SRF2015-TUPB067 http://cds.cern.ch/record/2058161 eng Keckert, Sebastian Kleindienst, Raphael Knobloch, Jens Kugeler, Oliver Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator Accelerators and Storage Rings 12: Innovative Radio Frequency Technologies (RF) 12.2: Thin films The systematic research on superconducting thin films requires dedicated testing equipment. The Quadrupole Resonator (QPR) is a specialized tool to characterize the superconducting RF properties of circular planar samples. A calorimetric measurement of the RF surface losses allows the surface resistance to be measured with sub nano-ohm resolution. This measurement can be performed over a wide temperature and magnetic field range, at frequencies of 433, 866 and 1300 MHz. The system at Helmholtz-Zentrum Berlin (HZB) is based on a resonator built at CERN and has been optimized to lower peak electric fields and an improved resolution. In this paper the design of an alternative calorimetry chamber is presented, providing flat samples for coating which are easy changeable. All parts are connected by screwing connections and no electron beam welding is required. Furthermore this design enables exchangeability of samples between the resonators at HZB and CERN. First measurements with the new design show ambiguous results, partly explainable by RF losses at the indium gasket. info:eu-repo/grantAgreement/EC/FP7/312453 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2058161 , (2015) pp. TUPB067 2015 |
spellingShingle | Accelerators and Storage Rings 12: Innovative Radio Frequency Technologies (RF) 12.2: Thin films Keckert, Sebastian Kleindienst, Raphael Knobloch, Jens Kugeler, Oliver Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator |
title | Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator |
title_full | Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator |
title_fullStr | Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator |
title_full_unstemmed | Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator |
title_short | Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator |
title_sort | design and first measurements of an alternative calorimetry chamber for the hzb quadrupole resonator |
topic | Accelerators and Storage Rings 12: Innovative Radio Frequency Technologies (RF) 12.2: Thin films |
url | https://dx.doi.org/10.18429/JACoW-SRF2015-TUPB067 http://cds.cern.ch/record/2058161 http://cds.cern.ch/record/2058161 |
work_keys_str_mv | AT keckertsebastian designandfirstmeasurementsofanalternativecalorimetrychamberforthehzbquadrupoleresonator AT kleindienstraphael designandfirstmeasurementsofanalternativecalorimetrychamberforthehzbquadrupoleresonator AT knoblochjens designandfirstmeasurementsofanalternativecalorimetrychamberforthehzbquadrupoleresonator AT kugeleroliver designandfirstmeasurementsofanalternativecalorimetrychamberforthehzbquadrupoleresonator |