Cargando…
Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2
The Detector Control System of the CMS Electromagnetic Calorimeter has undergone significant improvements during the first LHC Long Shutdown. Based on the experience acquired during the first period of physics data taking of the LHC, several hardware projects were carried out to improve data accurac...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/11/01/C01020 http://cds.cern.ch/record/2063664 |
_version_ | 1780948588846645248 |
---|---|
author | Holme, Oliver Adzic, P. Di Calafiori, D. Cirkovic, P. Dissertori, G. Djambazov, L. Jovanovic, D. Lustermann, W. Zelepoukine, S. |
author_facet | Holme, Oliver Adzic, P. Di Calafiori, D. Cirkovic, P. Dissertori, G. Djambazov, L. Jovanovic, D. Lustermann, W. Zelepoukine, S. |
author_sort | Holme, Oliver |
collection | CERN |
description | The Detector Control System of the CMS Electromagnetic Calorimeter has undergone significant improvements during the first LHC Long Shutdown. Based on the experience acquired during the first period of physics data taking of the LHC, several hardware projects were carried out to improve data accuracy, to minimise the impact of failures and to extend remote control possibilities in order to accelerate recovery from problematic situations. This paper outlines the hardware of the detector control and safety systems and explains in detail the requirements, design and commissioning of the new hardware projects. |
id | cern-2063664 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | cern-20636642022-08-10T12:45:21Zdoi:10.1088/1748-0221/11/01/C01020http://cds.cern.ch/record/2063664engHolme, OliverAdzic, P.Di Calafiori, D.Cirkovic, P.Dissertori, G.Djambazov, L.Jovanovic, D.Lustermann, W.Zelepoukine, S.Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2Detectors and Experimental TechniquesThe Detector Control System of the CMS Electromagnetic Calorimeter has undergone significant improvements during the first LHC Long Shutdown. Based on the experience acquired during the first period of physics data taking of the LHC, several hardware projects were carried out to improve data accuracy, to minimise the impact of failures and to extend remote control possibilities in order to accelerate recovery from problematic situations. This paper outlines the hardware of the detector control and safety systems and explains in detail the requirements, design and commissioning of the new hardware projects.CMS-CR-2015-252oai:cds.cern.ch:20636642015-10-21 |
spellingShingle | Detectors and Experimental Techniques Holme, Oliver Adzic, P. Di Calafiori, D. Cirkovic, P. Dissertori, G. Djambazov, L. Jovanovic, D. Lustermann, W. Zelepoukine, S. Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2 |
title | Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2 |
title_full | Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2 |
title_fullStr | Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2 |
title_full_unstemmed | Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2 |
title_short | Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2 |
title_sort | preparing the hardware of the cms electromagnetic calorimeter control and safety systems for lhc run 2 |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/11/01/C01020 http://cds.cern.ch/record/2063664 |
work_keys_str_mv | AT holmeoliver preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 AT adzicp preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 AT dicalafiorid preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 AT cirkovicp preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 AT dissertorig preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 AT djambazovl preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 AT jovanovicd preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 AT lustermannw preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 AT zelepoukines preparingthehardwareofthecmselectromagneticcalorimetercontrolandsafetysystemsforlhcrun2 |