Improvements of the optical detection setup of COLLAPS

In Collinear Laser Spectroscopy of rare isotopes it is crucial to keep the background of the measurements low. Using photomultiplier tubes for those measurements, the dark count rate should be as low as possible and the signal gain high. Therefore, it is important to use the right type of photomulti...

Descripción completa

Detalles Bibliográficos
Autor principal: Sailer, Stefan
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:http://cds.cern.ch/record/2066960
_version_ 1780948711193444352
author Sailer, Stefan
author_facet Sailer, Stefan
author_sort Sailer, Stefan
collection CERN
description In Collinear Laser Spectroscopy of rare isotopes it is crucial to keep the background of the measurements low. Using photomultiplier tubes for those measurements, the dark count rate should be as low as possible and the signal gain high. Therefore, it is important to use the right type of photomultiplier tubes for the purpose of single photon detection with a low signal rate. Thus, I tested several different types of photomultiplier tubes for their dark count rates and noise to signal separation. The results have identified the most suitable type of photomultiplier tubes, but further measuring for verification might be necessary. Therefore, it is very important to keep the photomultiplier tubes shut from light. Exposing the photocathode to light implies life-long damage and increased background for several days. So far, when dismounting one of these photomultiplier tubes from the setup, a big cage around the optical detection setup was covered into black sheets to keep it as dark as possible inside. Still, the photomultiplier tubes got exposured by some light. To avoid this, a shutter system was developed. This system contains a slit for reducing stray light, a system for adjustment of the distance between the photomultiplier tubes and some focusing lenses and the actual shutter, that can be closed in case of dismounting a photomultiplier tube. This shutter already has been tested and the results are promising.
id cern-2066960
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-20669602019-09-30T06:29:59Zhttp://cds.cern.ch/record/2066960engSailer, StefanImprovements of the optical detection setup of COLLAPSPhysics in GeneralIn Collinear Laser Spectroscopy of rare isotopes it is crucial to keep the background of the measurements low. Using photomultiplier tubes for those measurements, the dark count rate should be as low as possible and the signal gain high. Therefore, it is important to use the right type of photomultiplier tubes for the purpose of single photon detection with a low signal rate. Thus, I tested several different types of photomultiplier tubes for their dark count rates and noise to signal separation. The results have identified the most suitable type of photomultiplier tubes, but further measuring for verification might be necessary. Therefore, it is very important to keep the photomultiplier tubes shut from light. Exposing the photocathode to light implies life-long damage and increased background for several days. So far, when dismounting one of these photomultiplier tubes from the setup, a big cage around the optical detection setup was covered into black sheets to keep it as dark as possible inside. Still, the photomultiplier tubes got exposured by some light. To avoid this, a shutter system was developed. This system contains a slit for reducing stray light, a system for adjustment of the distance between the photomultiplier tubes and some focusing lenses and the actual shutter, that can be closed in case of dismounting a photomultiplier tube. This shutter already has been tested and the results are promising.CERN-STUDENTS-Note-2015-256oai:cds.cern.ch:20669602015-09-11
spellingShingle Physics in General
Sailer, Stefan
Improvements of the optical detection setup of COLLAPS
title Improvements of the optical detection setup of COLLAPS
title_full Improvements of the optical detection setup of COLLAPS
title_fullStr Improvements of the optical detection setup of COLLAPS
title_full_unstemmed Improvements of the optical detection setup of COLLAPS
title_short Improvements of the optical detection setup of COLLAPS
title_sort improvements of the optical detection setup of collaps
topic Physics in General
url http://cds.cern.ch/record/2066960
work_keys_str_mv AT sailerstefan improvementsoftheopticaldetectionsetupofcollaps